Page 7
Kryo
Series Power Amplifiers
acoustics
Standard Configuration:
the amplifier
works without Hi Pass subsonic filter,
Clip Limiter ICL enabled and no Bridge
mode.
Sub-sonic Filter Enabled:
the amplifier
works with Hi Pass subsonic filter
(30Hz in this case), Clip Limiter ICL
enabled and no Bridge mode.
ICL Clip Limiter Disabled:
the ampli-
fier works without Hi Pass subsonic fil-
ter, Clip Limiter ICL disabled and no
Bridge mode.
Installation and Operation
Configuration Switches
Bridge Mode:
the amplifier works
without Hi Pass subsonic filter, Clip
Limiter ICL enabled and Bridge mode.
The amplifier has a set of mini dip switches on the rear panel. These switches
allow the activation of the Hi Pass filter and its frequency, the activation of the ICL
clip limiter and bridge mode. Any of these configurations can be activated in any
way.
The basic configurations are as follows: