Page 11 of 15
Manual VENIA-8sp DDA - 2021-12 EN
Mounting the U-bracket
1. Remove the M10 countersunk screws on both sides of the co-
lumn line array.
2. Use the supplied M10 hexagon head screws (A) including pla-
stic washers to mount the U-bracket.
3.
To protect the coatings, place the plastic washers between the
hex bolt, U-bracket and the column line array.
Mounting the C-bracket
1. On the top and bottom of the column line array, remove the
two M10 countersunk screws in the rear area.
2. Use the supplied M10 hexagon head screws (B) including pla-
stic washers to mount the C-bracket.
3.
To protect the coatings, place the plastic washers between the
hex bolt, C-bracket and the column line array.
Working with VENIA-8sp DDA
A
B