INSTALLATION (VENT OUTSIDE)
MOUNTING OF THE V-FLAP
If the cooker hood does not have an assembled V-flap 1, you should mount the half-parts to its
body. The images only show an example of how to mount the V-flap,the outlet may be various
according to different models and configuration.
To mount the V-flap 1 you should:
• Mount two half-parts 2 into the body 6
• A pin 3 should be top oriented;
• The axis 4 should be inserted in the holes 5 on body;
• Repeat all the operations for the 2nd half-part
INSTALLATION
1. Before installation, turn the unit off and unplug it from the outlet.
2. The cooker hood should not be placed at a distance of no more than 150cm from the cooking
surface for the best performance. Refer to Pic 1.
3. The ceiling must can bear at least 120KGs weight, and the thickness of the ceiling must be
≥30MM.
4. According to the size shown on Pic 2, drill 14pcs
φ8mm holes on the ceiling once the installation height is
determined,14pcs explode screws(or 14pcs of ST6*40mm
big flat 14pcs wall plugs) will be used to fix the
two hanging board on the ceiling.( See Pic. 3)
5. Calculate the length of the angle iron(refer to Pic 4/5),then 32pcs of M4*10 screws and M4 nut
with gasket will be used to connect the angle iron into the adjustable angle iron bracket. (Make sure
the overlap length of angle iron cannot less than 36mm)