![Vogt P-34AL-15 Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/vogt/p-34al-15/p-34al-15_service-manual_1044453080.webp)
P34AL-15 & P34ALOF-15 Service Manual
TROUBLESHOOTING
9/22/05
8-5
Symptom: Freeze-up due to ice failing to discharge
Possible Cause
Possible Remedy
Freeze timer (1TR) set to long
Adjust timer or replace if defective. See
FIGURE 9-1.
Extended freeze period (if 2PS is used)
Check
freezer
pressure
switch
(2PS)
adjustment. See FIGURE 9-1 for adjustment
and TABLE 7-2 for average hole size. Make
sure all water distributors are in place (one in
each tube).
Thaw time too short (2TR)
Adjust thaw timer (2TR) to allow all ice to
clear the cutter and ice discharge opening with
at least 30 seconds to spare. Replace defective
timer. See pressure regulating valve adj.
Thaw pressure to low
The thaw gas regulator should be adjusted to
increase the pressure in the freezer to 60-65 psi
during a harvest. Isolate and repair or replace
the valve as needed.
Insufficient heat for thawing due to low
condensing pressure
The head pressure should be maintained from
175-190 psi (maximum 200) usually by a water
regulating valve or fan cycling switch. Check
to make sure these controls are working
properly. Cold prevailing wind can also be a
factor.
Insufficient heat due to non-condensables
(usually air) in the system
If non-condensables are present with the
refrigerant, the saturated temperature will not
relate to the pressure reading at the receiver
and the refrigerant will be cooler, although
pressure will be high. Air can be purged from
the system by following the procedure in the
Section 9, “Purging Non-Condensables”.
Insufficient heat due to low refrigerant charge
The refrigerant level in the receiver should be
near the operating mark at the end of a freezing
cycle to provide enough volume of warm gas
for harvesting. DO NOT OVERFILL
RECEIVER. See Table 3-2
Cutter or cutter disc does not turn
Check cutter gear reducer and drive gear for
proper operation and alignment. Check for
broken gear teeth or sheared shaft key.
Replace defective parts.
Compressor not running unloaded during thaw
cycle. (for dedicated high side only)
Check compressor motor Amp draw. During
the thaw cycle, the compressor motor Amp
draw should be 60 - 70% of normal amp draw
during the freeze cycle. Check compressor
unloader solenoid coil (UR) to make sure it is
energized and the valve opening during the
thaw cycle.
Содержание P-34AL-15
Страница 1: ...P 34AL 15 P34ALOF 15 TUBE ICE MACHINE Service Manual 5000 9 22 05 ...
Страница 2: ......
Страница 5: ...9 22 05 ...
Страница 8: ......
Страница 14: ...P34AL 15 P34ALOF 15 Service Manual TABLE OF CONTENTS vi ...
Страница 18: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 4 FIGURE 1 1 P34AL 15 Front Side Control Panel ...
Страница 19: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 5 FIGURE 1 2 P34AL 15 Right Side ...
Страница 20: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 6 FIGURE 1 3 P34AL 15 Left Side ...
Страница 21: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 7 FIGURE 1 4 P34ALOF 15 Front Side Control Panel ...
Страница 22: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 8 FIGURE 1 5 P34ALOF 15 Right Side ...
Страница 23: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 9 FIGURE 1 6 P34ALOF 15 Left Side ...
Страница 24: ...P34AL 15 P34ALOF 15 Service Manual INTRODUCTION 9 22 05 1 10 ...
Страница 50: ...P34AL 15 P34ALOF 15 Service Manual INSTALLING YOUR TUBE ICE MACHINE 9 22 05 3 24 ...
Страница 62: ...P34AL 15 P34ALOF 15 Service Manual START UP OPERATION 9 22 05 5 8 ...
Страница 88: ...P34AL 15 P34ALOF 15 Service Manual TROUBLESHOOTING 9 22 05 8 13 ...
Страница 101: ...P34AL 15 P34ALOF 15 Service Manual SERVICING OPERATIONS 9 22 05 9 13 Figure 9 5A Typical Cutter Assembly ...
Страница 102: ...P34AL 15 P34ALOF 15 Service Manual SERVICING OPERATIONS 9 22 05 9 14 Figure 9 5B Typical Water Tank Assembly ...
Страница 115: ...P34AL 15 P34ALOF 15 Service Manual Options and Accessories 9 22 05 10 1 10 Options and Accessories ...
Страница 119: ...P34AL 15 P34ALOF 15 Service Manual Options and Accessories 9 22 05 10 5 Figure 10 3 Wiring Schematic ...
Страница 130: ...P34AL 15 P34ALOF 15 Service Manual Options and Accessories 9 22 05 10 16 ...
Страница 131: ...P34AL 15 P34ALOF 15 Service Manual TABLES CHARTS 9 22 05 11 1 11 Tables Charts ...
Страница 138: ...Appendix A ...
Страница 141: ......
Страница 143: ...i ...
Страница 144: ...ii ...
Страница 145: ...1 ...
Страница 146: ...2 ...
Страница 147: ...3 ...
Страница 148: ...4 ...
Страница 149: ...5 ...
Страница 150: ...6 ...
Страница 151: ...7 ...
Страница 152: ...8 ...
Страница 153: ...9 ...
Страница 154: ...10 ...
Страница 155: ...1 ...
Страница 159: ...P24AL P34AL Service Manual INDEX 9 22 05 12 4 ...