background image

Page 2

 / BX42E-SN 

 

VGZ-005 / 20120202.0

www.vogelzang.com

Read All Instructions carefully.

1.  The installation of this stove must comply with your 

local building code rulings. Please observe the 
clearances to combustibles (see reference figures 
7–9). Do not place fuel, furniture or any other ob-
jects within the clearance area.

2.  Verify that the stove is properly installed before 

firing the stove for the first time. After read-
ing these instructions, if you have any doubt 
about your ability to complete your installation  
properly, you must obtain the services of a  
professional licensed installer familiar with all  
aspects of safe and correct installation.  DO NOT  
use temporar y or makeshift compromises  
during installation. There must be 

NO DEVIATION 

OR ALTERATION OF ANY KIND 

from the very 

specific instructions spelled out in this instruction 
manual as it pertains to the installation of this 
woodstove. 

 NO EXCEPTIONS!

3.  DO NOT store wood, kindling, flammable liquids 

or other combustible materials in the vicinity of the 
appliance. Refer to certification label on back of unit 
and reference figures 7–9 in this manual.

4. 

DO NOT INSTALL THIS STOVE IN A MOBILE 
HOME, MANUFACTURED HOME, TRAILER OR 
TENT NO EXCEPTIONS! (HUD Federal Stan-
dard: 24 CFR Ch.XX).

5. 

DO NOT ELEVATE THIS STOVE BY ANY MEANS. 

(i.e. bricks under legs, cement blocks)  Stove legs 
must set directly upon the solid-surface non-com-
bustible floor as specified in this stove instruction 
manual. 

6. 

DO NOT MODIFY THIS STOVE IN ANY WAY!  

Stove must be installed with legs provided, attached 
as shown in the instructions. Assemble only with 
original parts as supplied and shown in this manual. 

DO NOT OPERATE A STOVE THAT IS MISSING 
ANY PARTS!

 If any parts are missing or defective, 

please notify the dealer or manufacturer immedi-
ately. Replace missing, broken or worn parts with 
factory original or equivalent parts only.

7.  Do not tamper with combustion air control  

beyond normal adjustment capacities.

8.  Always connect this stove to a chimney and vent 

to the outside. Never vent to another room or in-
side a building. 

DO NOT CONNECT THIS UNIT 

TO A CHIMNEY FLUE SERVING ANOTHER  
APPLIANCE.

9. 

DO NOT CONNECT A WOOD BURNING 
STOVE TO AN ALUMINUM TYPE B GAS VENT. 

This is not safe. Use approved masonry or an 
Underwriters Laboratories Listed UL 103 HT 

Residential Type and Building Heating Appliance 
Chimney. Use a 6˝/152mm diameter chimney, 
that is high enough to give a good draft. (See  
specifics in Chimney Connections instructions).

10. Be sure that your chimney is safely constructed 

and in good repair. Have the chimney inspected 
by the fire department or a qualified inspector. Your 
insurance company should be able to recommend 
a qualified inspector. Chimney connector pipe must 
be in good condition. Replace if necessary before 
using stove.

11. Creosote or soot may build up in the chimney  

connector and chimney and cause a house/building 
fire. Inspect the chimney connector and chimney 
twice monthly during the heating season and clean 
if necessary. (see Service Hints). 

12.  In the event of a chimney fire, turn the air con-

trol and flue damper to closed position, leave the 
building and 

CALL THE FIRE DEPARTMENT  

IMMEDIATELY!

  Have a clearly understood plan 

on how to handle a chimney fire by contact-
ing your local fire authority for information on 
proper procedures in the event of a chimney fire.  
After the fire is out, the chimney must be cleaned 
and inspected for any stress or cracks before starting 
another fire.  Check the condition of any combustibles 
surrounding the chimney.

13.  Ashes should not be allowed to accumulate above 

the top of the hearth plate.

14. 

DISPOSAL OF ASHES

 Ashes should be placed in 

a steel container with a tight fitting lid and moved 
outdoors immediately. The closed container of 
ashes should be placed on a noncombustible floor 
or on the ground, well away from all combustible 
materials, pending final disposal. If the ashes are 
disposed of by burial in soil or otherwise locally 
dispersed, they should be retained in the closed 
container until all cinders have completely cooled. 
Other waste shall not be placed in this container.

15.  To prevent injury, do not allow anyone to use this 

stove who is unfamiliar with the correct operation 
of the stove.

16.  Do not operate stove while under the influence of 

drugs or alcohol.

17. The special paints used on your stove may give 

off some smoke and an odor while they are curing 
during the first 12 to 15 fires. Additional smoke 
and odor may be emitted from the light oils used in 
construction of the fire box. This should disappear 
after a short period of time and not occur again. 
Persons with lung conditions or owners of sus-

continued on next page

SAFETY INSTRUCTIONS

Содержание DELUXE BOXWOOD BX42E

Страница 1: ...ichigan 49423 www vogelzang com Phone 1 616 396 1911 Fax 1 616 396 1971 DELUXE BOXWOOD STOVE Model BX42E Owners Manual save this manual for future reference NOTE THIS STOVE IS NOT A UL LISTED STOVE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS STOVE FAILURE TO FOLLOW INSTRUC TIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH REFER TO MARKINGS ON STOVE LABELS FOR ...

Страница 2: ...sonry or an Underwriters Laboratories Listed UL 103 HT Residential Type and Building Heating Appliance Chimney Use a 6 152mm diameter chimney that is high enough to give a good draft See specifics in Chimney Connections instructions 10 Be sure that your chimney is safely constructed and in good repair Have the chimney inspected by the fire department or a qualified inspector Your insurance company sh...

Страница 3: ...UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS 30 A WOOD BURNING STOVE MUST NEVER BE INSTALLED IN A HALLWAY OR NEAR A STAIR CASE as it may block egress in the event of a fire 31 DO NOT INSTALL IN A SLEEPING ROOM SAFETY INSTRUCTIONS continued DO NOT INSTALLTHIS UNIT IN AN ALCOVE OR INSIDE A FIREPLACE 32 Install at least one smoke detector on each floor of your home Detectors should be located aw...

Страница 4: ...erating Instructions House Fire Hazards Operating Precautions Warnings 12 Wood Types Sizes 12 Starting a Fire 12 Adding Fuel 13 Service Hints Creosote Formation Prevention Need for Removal 13 Stove Joints 14 Gasket Replacement 14 Parts Deluxe Boxwood 15 Floor Protector Calculations 16 Chimney Connection Systems Clearances 17 NOTE A PROFESSIONAL LICENSED HEAT ING AND COOLING CONTRACTOR MUST BE CONS...

Страница 5: ... Flooring Protection 52 x 74 as specified see page 3 Chimney Connection 6 black steel 24 ga min straight or elbow as required 1 2 Sheet Metal Screws Chimney Existing 6 Lined Ma sonry Chimney or 6 Inside Dia listed Type HT chimney Furnace Cement manufacturer recommends Rutland Code 78 or equivalent NOTICE Vogelzang International Corp grants no warranty stated or implied for the installation or maint...

Страница 6: ...th ods see page 16 Floor protector must extend at least 18 beyond the front of the hearth to the sides and beyond the rear of the stove The area under a horizontal run of the chimney connector must also be protected extending two 2 inched beyond the outer dimension of the horizontal connector The minimum sized floor protector for this stove is 52 x 74 Consult local building codes and fire protection...

Страница 7: ...ng codes or fire protection ordinances NOTE ANY WALL CONTAINING COMBUSTI BLEMATERIALSUCHASWOODENSTUDSOR DRYWALLANDFACEDWITHBRICKORSTONE MUST BE CONSIDERED A COMBUSTIBLE SURFACE 6 DO NOT INSTALL THIS STOVE IN A MOBILE HOME MANUFACTURED HOME TRAILER OR TENT NO EXCEPTIONS HUD Federal Stan dard 24 CFR Ch XX Figure 7 Minimum Clearance Dimensions from Combustible Surfaces 7 The clearances provided are m...

Страница 8: ...h the crimped end towards the stove This will allow any condensation in the flue to run back into the firebox 2 Horizontal pipe runs must slope upwards towards the chimney at least 1 4 6 4mm per foot of horizontal run 3 You must have at least 18 457mm of clearance between any horizontal piping and the ceiling 4 The pipe cannot extend into the chimney flue figure 9 5 Secure pipe elbow sections with th...

Страница 9: ...verse effect on the draft The manufacturer cannot be held responsible for external factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling con tractor for assistance in solving the problem IMPORTANT Installation Points 1 Size chimney flue to stove collar This stove requires a minimum of a 6 152mm diameter flue 2...

Страница 10: ...c com or www mtlfab com VENTING TO EXISTING FIREPLACE In some instances people desire to convert an ex isting fireplace for stove use Usually safe connection to an existing masonry chimney requires more work than using a prefabricated chimney The existing fireplace must be closed and sealed at the damper with high temperature caulk ceramic wool or furnace cement Prior to installation clean and inspe...

Страница 11: ... installer 1 An entry hole must be cut through the masonry and tile liner with minimal damage to the liner At least 8 of liner must remain below the entry position When locating the stove and stovepipe all minimum clear ances must be observed from combustible surfaces including mantels combustible trimwork ceilings and walls Positioning the center of the stove pipe entry into the chimney 24 below ...

Страница 12: ... fire is burning briskly Use care not to smother the kindling fire when adding wood Close the door and secure tightly 6 Adjust the collar draft damper and door spin draft control The more closed the spin draft is set the lower and slower the fire will burn The more open the faster and hotter the fire will burn Do not over fire the stove continued on next page CAUTION HOUSE FIRE HAZARDS s 4 34 2 7 2 02 ...

Страница 13: ...ORS OR STOVE GLOWS RED IMMEDIATELY CLOSE THE DOOR DAMPER AND SPIN DRAFTTO RE DUCETHE AIR SUPPLY AND SLOW DOWNTHE FIRE TOO MUCH WOOD OR BURNING NON RECOMMENDED MATERIALS SUCH AS TRASH OR FLAMMABLE LIQUIDS MAY CAUSE OVER FIRING continued on next page CAUTION DO NOT OVER FIRE APPLIANCE CAUTION SLOW BURNING FIRES AND EX TENDED USE MAY CAUSE EXCESSIVE CREO SOTE BUILDUP IGNITION OF CREOSOTE BUILDUP OR O...

Страница 14: ...w Smoke spillage into the house or excessive buildup of condensation or creosote in the chimney are warnings that the chimney is NOT functioning properly Correct the problem before using the stove Following are some possible causes for improper draft 1 The connector stovepipe may be pushed into the chimney too far stopping the draft 2 If the chimney temperature is too cool water will condense in t...

Страница 15: ... identify parts Contact us at 616 396 1911 to order parts Part No Description Qty 42 01 Leg 4 42 02 Bottom 1 42 03 Side 2 42 04 Back 1 42 05 Front 1 42 06 Door 1 42 07 Top 1 42 08 Damper Slide Draft 1 42 09 Lid 2 42 10 Lid Support 1 42 11 Hearth 1 42 12 Damper Collar Assembly 1 42 13 Handle Assembly 1 42 14 Lid Lifter L 1 1 42 15 42 16 S Hook used to hang lid lifter 1 42 17 Spin Draft 1 42 18 Door...

Страница 16: ...tector a Use formulas in step 1 above to calculate R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu inch W Btu ...

Страница 17: ...ls separated from combustibles by a minimum of 6 152mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connector and having 1 25 4mm or more of insulation serving as a pass through ...

Страница 18: ... be treated with respect Stay warm and in good health Respectfully yours Proprietor COMPANY TESTIMONY Vogelzang International Corporation 400 West 17th Street Holland Michigan 49423 www vogelzang com Phone 1 616 396 1911 Fax 1 616 396 1971 FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON THAT WHOEVER BELIEVES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE JOHN 3 16 MADE IN CHINA SteveV...

Отзывы: