VocoPro CLG-600 Скачать руководство пользователя страница 9

8

Front Panel Description and Controls 

(cont.)

4. IN/OUT button

 - This switch enables you to quickly 

hear the CLG-600 compressor/limiter IN or OUT of the 

audio chain. When the switch is in the OUT position, 

all limiting and compression controls and functions 

are bypassed, with the exception of the gain and 

output controls, which continue to function as 

straightforward level controls.

5. THRESHOLD control 

- The THRESHOLD control 

has a range of -40dB to +20 dB, allowing applications 

from low level compression to high level limiting. The 

THRESHOLD control determines the audio level above 

which GAIN REDUCTION occurs. When the 

THRESHOLD LED comes on, that means that GAIN 

REDUCTION is beginning to occur, due to input signal 

peaks exceeding the selected threshold in dB.

6. RATIO control

 - This control determines the RATIO 

of change in 

output level

 to changes in 

input level

 

for all signals above threshold. The numbers printed 

around the RATIO control are calibrated in dB and 

indicate the increase in input (above threshold) 

required to produce a 1db increase in output. This 

can be expressed conveniently as a ratio. If the 

output

 remains constant no matter how high the 

input level, we have an infinite input/output ratio. 

NOTE: It should be remembered that the RATIO 

control has no effect on signals which are below 

threshold

. There is a common but incorrect 

notion that limiting always implies the use of an 

infinite ratio. Although there are times when an 

infinite ratio is desirable, there will be situations 

where infinite, or "hard", limiting action is neither 

appropriate nor necessary.

7. ATTACK control

 - ATTACK controls how fast the 

compressor reacts to signals passing 

over

 the 

threshold point

. The available range is from 0.1 to 

200 ms. This control when used correctly creates 

either a smooth or abrupt signal process.

8. RELEASE control

  - The RELEASE control 

determines how fast or slow a compressed 

segment returns to its original volume. The 

available range is from .05 to 4 seconds. This 

control when used correctly creates either a 

9. AUTO/MANUAL switch

 - By activating the AUTO 

switch to the ON position, the 

attack

 and 

release 

controls are handled by the CLG-600 

automatically

.  When it is set to the MANUAL 

position, the 

attack

 and 

release

 controls will 

adhere to settings of the controls in place. This 

allows for unobtrusive musical compression with 

widely varying dynamics to occur without 

"manning" the sound system.

10. OUTPUT LEVEL control 

- OUTPUT Level control 

is provided to fully cut or restore up to -/+ 20 dB 

of 

system gain

. For unity gain, set the control to 0. 

NOTE:

 

When the unit is in the BYPASS mode the 

output

 control still functions.

11. GAIN REDUCTION meter

 - This 8-stage LED 

meter indicates the actual GAIN REDUCTION 

processing level and displays this in range 

of 0-30 dB.

12. LEVEL EXPANSION meter 

- This 8-stage meter 

indicates the actual LEVEL EXPANSION level and 

displays this in a range of -30dB to +6dB.

LEVEL

THRESHOLD

dB

MANUAL

AUTO

COMPRESSOR/LIMITER

RATIO

M1

RELEASE

Sec

O U P U T

dB

CH 1

            30        27        24        21        18        15        12         9          6          4          2           1 

GAIN

OUT

 -30        20        -10        -5         -3          0         +3        +5

+20

+10

0

-10

-20

-30

-40

2.5

1

1.5

8

200

2.5

0.1

4

.05

0.5

-20

+20

0

OFF

msec

IN

4

5

6

7

8

9

10

11

12

Содержание CLG-600

Страница 1: ...IRC Interactive Ratio Control Expander Gate Automatically Adjusts Expansion Per the Program Material Eliminating the Noise Floor During Quiet Sections or Music Pauses 1 4 and XLR TRS Input Outputs Pr...

Страница 2: ...other appliances including amplifiers that produce heat 10 Power Sources The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on t...

Страница 3: ...8 Curtiss Court La Verne CA 91750 Toll Free 800 678 5348 TEL 909 593 8893 FAX 909 593 8890 VocoPro Company Email Directory Customer Service General Information info vocopro com Tech Support techsuppor...

Страница 4: ...al and leave it there Pay attention to the different levels in various recordings Taking a minute to do this now will help to prevent hearing damage or loss in the future After all we want you listeni...

Страница 5: ...on Ratios and Threshold Levels Allow Both the Novice and the Experienced User Full Effective Use All Processing Controls Dual 12 stage Gain Reduction and 8 stage Input Output Meters for Accurate Relia...

Страница 6: ...d to as Compressing Also common is the application of completely removing audible noise from low volume sections of an audio signal i e fans air conditioning units electric hums This is referred to as...

Страница 7: ...k instructions for proper hardware An oval head or flat head screw with a plastic countersink washer is preferred to protect the finish of the CLG 600 under the screw The CLG 600 is housed in a rugged...

Страница 8: ...20 10 0 10 20 30 40 2 5 1 1 5 8 200 2 5 0 1 4 05 0 5 20 20 0 OFF 3 6 msec IN STEREO MODE 35 DUAL CHANNEL COMPRESSOR LIMITER WITH GATE CLG 600 INAUDIBLE THRESHOLD dB EXPANDER GATE 35 50 OFF 10 0 10 35...

Страница 9: ...e there will be situations where infinite or hard limiting action is neither appropriate nor necessary 7 ATTACK control ATTACK controls how fast the compressor reacts to signals passing over the thres...

Страница 10: ...ce 15 FUSE housing This is where the CLG 600 s fuse resides If for any reason the fuse blows it is recommended to seek assistance from a technician prior to re installing another fuse due to the fact...

Страница 11: ...gain increased to induce another feedback point and the whole procedure is repeated until the engineer is satisfied that the significant problem frequencies have been corrected The major problem with...

Страница 12: ...predominant feedback frequencies 6 Return all mixer EQ overall gain and compressor limiter gain controls to normal settings Typical Applications cont Recording The limiter can be used to prevent tape...

Страница 13: ...erfect A little compression helps to keep their quieter lines from becoming buried in the mix Experimentation is highly recommended Voice Over Compression Ducking The CLG 600 units can be used to auto...

Страница 14: ...e program source or use less compression No Output Check AC power Is the power switch on Check input and output connections are they reversed Are you sure you have an input signal Controls Have No Eff...

Страница 15: ...uld give a good amount of punch Big Radio Voice Gate Off Threshold 20db Ratio 6 1 Attack Fast Release Slow Output 10db Drums Gate 30db Threshold 15db Ratio 4 1 Attack Fast Release Medium Output 10db I...

Страница 16: ...e 40 to 20 dBu Ratio Variable 1 1 to LM Attack Variable 0 1 to 200 msec 20dB Release Variable 0 05 to 4 sec 20dB Output Variable 20 to 2 dB GATE SECTION Type IRC Interactive Knee Control Threshold Var...