VocoPro CLG-600 Скачать руководство пользователя страница 16

15

AUDIO INPUT

Type RF filtered, servo-balanced input stage

Impedance 60 k Ohms, balanced

Nominal Operating Level -10 dBu to +4 dBu

Max. Input Level +21 dBu balanced and unbalanced

CNR @ 1 kHz >40 dB

DETECTOR INPUT

Type DC de-coupled, unbalanced input

Impedance <20k Ohms 

Max. Input Level +20 dBu

AUDIO OUTPUT

Type Electronically buffered output stage<40 Ohms 

Impedance <40 Ohms

Max. Output Level +20 dBu

Bandwidth 5Hz to 50 kHz, +0, -1 dB

THD @ +4 dBu 0.05% typ

THD @ -10 dBu 0.1% typ

IMD (SMPTE) @ +10 dBu 0.01% typ

Noise & Hum, Unity Gain >-93 dBu

Noise & Hum, Fully Off>-97 dBu >-97 dBu

Crosswalk @ 20 kHz>-85 dBu >-85 dBu

CMR @ 1kHz> 60 dB >-60 dBu

COMPRESSOR SECTION

Type IKC (Interactive Knee Compressor)

Threshold Variable (-40 to +20 dBu)

Ratio Variable (1:1 to LM)

Attack Variable (0.1 to 200 msec/20dB)

Release Variable (0.05 to 4 sec./20dB)

Output Variable (-20 to +2- dB)

GATE SECTION

Type IRC (Interactive Knee Control)

Threshold Variable (Off to +10 dB)

DYNAMIC ENHANCER SECTION

Type  Dynamically controlled frequency correction

Process Variable (Off to 6) 

FUNCTION SWITCHES

In/Out Bypass switch

Auto Program-dependent attack and release times

INDICATORS

CLOSE LED indicates onset of the expander gate

8-Element Gain Reduction Meter 1/4/6/10/15/20/30/dB

POWER SUPPLY

Mean Voltages 115V-120V/230V/240V VAC 30-60 Hz

Power Consumption 9 watts

Fuse 320mA (115V)160mA (230V) slow-blow 

PHYSICAL

Dimensions 1.74" (H) x 19" (W) x 8.5" (D)

Net Weight 6.6 lbs.

Shipping Weight 9.5 lbs.

Specifications

For improvement purposes, modifications may be made from time to 

time without prior notice. Specifications may differ from those above

Содержание CLG-600

Страница 1: ...IRC Interactive Ratio Control Expander Gate Automatically Adjusts Expansion Per the Program Material Eliminating the Noise Floor During Quiet Sections or Music Pauses 1 4 and XLR TRS Input Outputs Pr...

Страница 2: ...other appliances including amplifiers that produce heat 10 Power Sources The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on t...

Страница 3: ...8 Curtiss Court La Verne CA 91750 Toll Free 800 678 5348 TEL 909 593 8893 FAX 909 593 8890 VocoPro Company Email Directory Customer Service General Information info vocopro com Tech Support techsuppor...

Страница 4: ...al and leave it there Pay attention to the different levels in various recordings Taking a minute to do this now will help to prevent hearing damage or loss in the future After all we want you listeni...

Страница 5: ...on Ratios and Threshold Levels Allow Both the Novice and the Experienced User Full Effective Use All Processing Controls Dual 12 stage Gain Reduction and 8 stage Input Output Meters for Accurate Relia...

Страница 6: ...d to as Compressing Also common is the application of completely removing audible noise from low volume sections of an audio signal i e fans air conditioning units electric hums This is referred to as...

Страница 7: ...k instructions for proper hardware An oval head or flat head screw with a plastic countersink washer is preferred to protect the finish of the CLG 600 under the screw The CLG 600 is housed in a rugged...

Страница 8: ...20 10 0 10 20 30 40 2 5 1 1 5 8 200 2 5 0 1 4 05 0 5 20 20 0 OFF 3 6 msec IN STEREO MODE 35 DUAL CHANNEL COMPRESSOR LIMITER WITH GATE CLG 600 INAUDIBLE THRESHOLD dB EXPANDER GATE 35 50 OFF 10 0 10 35...

Страница 9: ...e there will be situations where infinite or hard limiting action is neither appropriate nor necessary 7 ATTACK control ATTACK controls how fast the compressor reacts to signals passing over the thres...

Страница 10: ...ce 15 FUSE housing This is where the CLG 600 s fuse resides If for any reason the fuse blows it is recommended to seek assistance from a technician prior to re installing another fuse due to the fact...

Страница 11: ...gain increased to induce another feedback point and the whole procedure is repeated until the engineer is satisfied that the significant problem frequencies have been corrected The major problem with...

Страница 12: ...predominant feedback frequencies 6 Return all mixer EQ overall gain and compressor limiter gain controls to normal settings Typical Applications cont Recording The limiter can be used to prevent tape...

Страница 13: ...erfect A little compression helps to keep their quieter lines from becoming buried in the mix Experimentation is highly recommended Voice Over Compression Ducking The CLG 600 units can be used to auto...

Страница 14: ...e program source or use less compression No Output Check AC power Is the power switch on Check input and output connections are they reversed Are you sure you have an input signal Controls Have No Eff...

Страница 15: ...uld give a good amount of punch Big Radio Voice Gate Off Threshold 20db Ratio 6 1 Attack Fast Release Slow Output 10db Drums Gate 30db Threshold 15db Ratio 4 1 Attack Fast Release Medium Output 10db I...

Страница 16: ...e 40 to 20 dBu Ratio Variable 1 1 to LM Attack Variable 0 1 to 200 msec 20dB Release Variable 0 05 to 4 sec 20dB Output Variable 20 to 2 dB GATE SECTION Type IRC Interactive Knee Control Threshold Var...

Отзывы: