Depósito legal y Copyright 2006. Todos los derechos reservados.
5. MAINTENANCE.
5.1 -
Regularly check the state of the cable. If
the cable has broken threads, or if it shows any
signs of crushed/flattened areas, it should be
changed and replaced immediately with a new
one. Do not use the lift if the cables are in bad
condition. Only use steel cables reference:
DIN 3060 torsion resistant.
5.2 -
The lift is supplied from the factory
completely greased. Howev er , it is
recommended to periodically grease according
to use, the gearing, the axis bearings, the
spiral of the crank, and the sections.
REMEMBER: NEVER grease or lubricate
the breaking mechanism.
It is not necessary to grease the brake
disks. The brake disks have been greased
with a special heat and pressure resistant
solution. Other products should not be used
to avoid negative effects regarding the brak-
ing mechanism.
5.3 -
An expert should check the TL-072 at
least once a year according to its usage.
Consult your distributor.
5.4 -
Only original replacement parts should be
used to guarantee continued safety during
usage.
The user loses all guarantee rights if he/she
uses replacement parts that are not original
or if he/she makes any modification to the
apparatus.
5.5 -
To order any replacement parts, the
reference number on the replacement parts
pages in this manual should be indicated.
Quick Operation Guide
ENGLISH
7. CERTIFICATIONS
-
EC Machinery Directive
89/392/ECC and 98/37/ECC
- BGV C1 (GUV-VC1) / BGG 912 (GUV-G912)
6. GUARANTEE.
If the during the guarantee period because of
poor workmanship or faulty materials VMB
Española, S.A. will repair or replace it.
The guarantee period for Europe is at 2
years.
The guarantee does not cover damage
caused by improper use, wear and tear
unauthorised repairs. The guarantee does not
cover consumables or defects that have only
a negligible effect on the value or operation of
the elevator tower.