Eccellenza Express – Operating Manual
80
August 8, 2013
MESSAGE DISPLAYED
CAUSE
POSSIBLE REMEDIES
Factory Settings
Version Error
The version of Factory
Settings is not compatible
with the machine model.
•
Load the proper version of Factory
Settings.
Filling Water Tank
The water tank is filling.
•
Normal operating message and does
not indicate an error.
Finding Brewer Home
Brewer is cycling to find
the home (starting)
position.
•
Normal operating message and does
not indicate an error.
Heating Water
Water inside the hot
water tank is heating.
•
Normal operating message and does
not indicate an error.
LCD Error
An error has been
detected with the LCD
display.
•
Verify the wiring connections to the
LCD display.
•
Replace the LCD display.
Money System Error
The coin changer is not
being detected.
•
Verify the wiring connections at the
control board and inside the changer
unit.
•
Replace the defective coin changer.
Overflow Error
A water overflow has
been detected.
•
Empty and dry the overflow/cup tray.
•
Verify the water level probe
adjustment. They may be set too high
allowing too much water into the tank.
•
Water level probes may need to be
cleaned.
•
Inlet valve may be leaking,
constantly allowing water to enter the
tank. Replace the inlet valve.
•
Water in the tank may be boiling.
Lower the water temperature setting.
Overheat Error
The water tank is
overheating.
•
Check the temperature settings in
the set-up.
•
The temperature probe may need to
be replaced.
PnB not Detected
The control board is not
being detected.
•
The USB cable is not connected to
the control board or the expansion
board. Verify the connections.
Port J10 Not Detected
Wiring harness is
disconnected from port 10
on the control board.
•
Reconnect the wiring harness to port
10 on the control board.
Port J23 Not Detected
Wiring harness is
disconnected from port 23
on the control board.
•
Reconnect the wiring harness to port
23 on the control board.
Powersaving Mode –
Press Start to Exit
The machine is in
Powersaving Mode.
•
Press the Start button to exit
Powersaving Mode.