background image

FUNCTIONAL CHECK

PROGRAMMING

1. Lock type

ML

EL

2.  Unlocked state duration (1 to 12 seconds)

3. Volume of messages (Minimum / Medium / Maximum)

Medium

A

the

the

Adjust brightness, contrast and colour, if needed.

There are two modes of programming: system setup and service settings.

Electromagnetic lock (

) is released when voltage across its terminals is switched off.

Electromagnetic lock is set by default.

Electromechanical lock (

) is released when voltage across its terminals is switched on.

Default setting is 7 seconds.
1 second is recommended for electromechanical lock.

Default setting is

System setup

Before switching the power on verify all electric connections.
Turn the power supply on. The lamps illuminate on each side of the   camera.

Press the

button on the doorstation - a beep  sounds at

apartment  monitor  while  the  button  remains

pressed, image appears on

screen.

Pick up the handset and check duplex intercom. Hang up the handset when finished.

=

=

Figure 2 -  Doorstation  wall-mounting

Содержание BVD-407 Series

Страница 1: ...re supported Only keys DS1990A iButton from Dallas Semiconductor are supported Intercom between visitor and subscriber Door zone videomonitoring Illumination for the camera The entrance door unlocking...

Страница 2: ...ine carefully the operating instruction for the installation order and wiring diagrams Mounting dimensions are shown on Figure 1 in millimeters The doorstation center should be approximately 1 5 meter...

Страница 3: ...default Electromechanical lock is released when voltage across its terminals is switched on Default setting is 7 seconds 1 second is recommended for electromechanical lock Default setting is System se...

Страница 4: ...in part Programming After the programming is complete press the button sounds and the doorstation returns into stand by mode You can enter programming mode using the MASTER key memorized during the fi...

Страница 5: ...f cables 0 4 A B C D E meters 50 2 1 1 2 18 18 12 12 Power supply BPD18 12 1 1 Doorstation BVD 407x LN GND E Ec LC VO VG OP 2 1 3 3 2 E Figure 5 Transitions between system setup service settings and P...

Страница 6: ...1 A 6 MASTER key memorizing strokes Beep Apply a key to be the MASTER key which is Figure 6 Transitions in system setup mode Figure 7 Transitions in service settings mode 1 Memorizing of keys stroke o...

Страница 7: ...e system goes into Stand by mode Check operation of all keys If the applied key is memorized the door unlocks Come in please sounds at the doorstation and a short beep sounds at the monitor If the app...