www.
5
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision
12)
vizit-group.com
7 10
/
201 -
Figure 10 - 4-apartment video doorphone with outdoor camera and
video monitors
powered from a group power supply unit
VIZIT*
Circuit
length, m
Circuits
25
0.25
0.5
50
BVD
A
-405 -4
Monitors
Min. wire cross-
section, mm
BPD
1
Lock
18/12- -1
BPD
1
18/12- -1
-405 -4
BVD
A
0.5
1.0
BPD24/12-1-1
RVE 4 Monitors
-
BPD24/12-1-1
Outdoor Camera
RVE 4
-
Outdoor Camera
Monitors
0.5
1.0
2
Power Supply Unit
/12- -1
BPD24
1
GND
+12V
+24V
GND
LN
FC
FD
FA
FB
+E
GND
BVD
5A-4
Doorstation
-40
LINE
LC
FB
+E
FA
GND
FD
FC
GND
+12V
Jumper
shall be
set up
Z
LN
FD
LN
FC
LN
FB
LN
FA
+EA
VOA
VGA
GA
Outdoor Camera
VIZIT-C70
+24V
GND
+E
GND
Power Supply Unit
18/12- -1
BPD
1
-18
+18
+12
-12
VO
LN-
GND
LN+
VI1
+E
Monitor
VIZIT*
Apt. 1
LN-
GND
LN+
VI1
+E
Monitor
VIZIT*
Apt. 2
LN-
GND
LN+
VI1
+E
Monitor
VIZIT*
Apt. 3
LN-
GND
LN+
VI1
+E
Monitor
VIZIT*
Apt. 4
* - video monitors that may be
used in this diagram:
VIZIT-M4
VIZIT-M4
VIZIT-M4
VIZIT-M4
VIZIT-M4
VIZIT-M4
27C
40C
40CM
41M
41M
56CM
VIZIT-M4
VIZIT-M4
56C
57M
1N4007
Electromechanical lock / strike
12V / 0.6A max.
+EA
VGA
GA
VOA
VO
Z
VG
VG
VI
+E
+E
G
G
Distribution Amplifier
RVE-4
+EB
VGB
GB
VOB
+EC
VGC
GC
VOC
FA
FB
FC
FD
+EA
VGA
GA
VOA
+ED
VGD
GD
VOD
+ED
VGD
GD
VOD
+EC
VGC
GC
VOC
+EB
VGB
GB
VOB
+EB
VOB
VGB
GB
+EC
VOC
VGC
GC
+ED
VOD
VGD
GD
+24V
GND
GND
+12V
green
black
red
VI
VG
VI
VG