CONFIDENTIAL – DO NOT COPY
Page 2-2
File No. SG-0243
6. ENVIRONMENT
Operating Temperature: 5c~35c (Ambient).
Operating Humidity: Ta= 35 °C, 90%RH (Non-condensing).
Operating Altitude: 0 - 14,000 feet (4267.2m)(Non-Operating).
7. DIMENSIONS (Physical dimension)
:
Dimensions with stand 1131mm(H)*798mm(W)*269mm(D).
:
Dimension without stand 1131mm(H)*755.6mm(W)*125.5mm(D).
8. WEIGHT (Physical weight)
Net
:
36.0 +/- 0.5 kgs.
Gross
:
43+/- 0.5 kgs.
Precaution
Please pay attention to the followings when you use this TFT LCD module.
1. OPERATING PRECAUTIONS
(1) The spike noise causes the mis-operation of circuits. It should be lower than
following voltage : V=±200mV(Over and under shoot voltage)
(2) Response time depends on the temperature. (In lower temperature, it becomes
longer.)
(3) Brightness depends on the temperature. (In lower temperature, it becomes
lower.)And in lower temperature, response time (required time that brightness is
stable after turned on) becomes longer.
(4) Be careful for condensation at sudden temperature change. Condensation
makes damage to polarizer or electrical contacted parts. And after fading
condensation, smear or spot will occur.
(5) When fixed patterns are displayed for a long time, remnant image is likely to
occur.
(6) Module has high frequency circuits. System manufacturers shall do sufficient
suppression to the electromagnetic interference. Grounding and shielding
methods may be important to minimize the interference.