background image

Warning

www.vizaar.com

The device can be connected to the public electric supply mains through a ‘IEC-plug lead’ included
in the delivery or a ‘IEC-plug lead’ which complies with the local socket standards. The system ac-
cepts faultlessly all power supplies known worldwide with alternate currents of 96 VAC to 246 VAC
at 46 to 60 Hz. For safe operation, the device needs a reliable potential earth (PE) connection. In case
of doubt, an expert or the manufacturer must be consulted. The minimum output supplied by the
power connection can be derived from the device specifications contained in the instructions.

:: Warning

When operating the device outside the permissible operating conditions or with destruction caused
by usage which deviates from the instructions, non-compliance with the operating conditions or
through the usage of non-original spare parts or accessories as well as through impermissible ope-
ning of the device, the guarantee obligation or the guarantee commitment by the supplier or manu-
facturer lapses, in principle.

All components of the device must never be used in or in the vicinity of apparatus or equipment,
which are partly or fully energized by electric current of any type (e.g. transformers, motors, gene-
rators, switchboards etc.). The metallic housing oaf the camera conducts electricity and dangerous
currents are transmitted during every contact or even short-circuits can be triggered in the plant.

While connecting to the car’s voltage transformer, the base unit should be connected to
protective earth and the car body, even when a grounding plug is available.

Never connect a triploar plug to a bipolar socket! Avoid any contact between INVIZ

®

/ MATRIX

(and all working equipment) and components carrying electrical charges.

The system must be earthed properly in case of an electrified application in relationship to the
ground. If impossible, connect the system to the application or the ground (depending on which one
the user needs to touch). The user needs to be isolated against the current path of the earthed path.

In case an exchange of the lamp becomes necessary, one must proceed according to the procedure
in the instructions!

Never handle the main cable without working gloves! Considerable risk of getting injured! At the
same time, protective glasses must always be worn while operating the system.

The device must never be operated with damaged main cable. There is a danger that liquids might
penetrate the cable and thereby impair the functioning permanently or might cause a life threate-
ning electric shock to the operator! Even the use of a slightly damaged main cable can quickly lead
to the total destruction of the device due to the electric conductors laying inside. The operation of a
damaged main cable is impermissible within the area of jurisdiction of the European Union, since the
regulations on emission of electromagnetic radiation can no longer be adhered to with safety.

Never bring the device in contact with corrosive substances of any kind (acid or alkali).
Risk of damage and injury while manipulating the main cable and camera head. Never bring the
device in contact with solvent containing liquids! Risk of damage!

Never insert the device in plant parts the contents of which are unknown!

Always ensure that the respectively inspected metallic pipeline systems conform exclusively to a
homogenous earthing potential; electrically insulated transition points (e.g. sealings, plastic line
sections) can exhibit different electric earth voltage potentials depending upon the plant, which could
build up very high electric currents with sparking and substance burn-out in case of bridging through
the metallic, electrically conducting probe. Kindly consult your on-site expert in advance.

Содержание INVIZ MATRIX

Страница 1: ...Short Guide www vizaar com Revision 2 59T INVIZ MATRIX...

Страница 2: ...ler main cable system and video processor Even plenty accessories will be the same and finally of course the working environment in any power or chemical plants plus refineries In order to obtain the...

Страница 3: ...creen digital high resolution image display joystick camera control text and data control Future inspection equipment VISIO BOX and VISIO probe systems Existing analogue video documentation Existing i...

Страница 4: ...and flexible fiberscopes using a video adapter Utilize the image analy sis documentation and storage performance of your INVIZ MATRIX COMPLETE THE FULL RANGE OF INSPECTION EQUIPMENT WORKING FROM AND...

Страница 5: ...accordance with the regulations viZaar is not liable under any circumstances for the consequences of misinterpretation or faulty inspection results which were achieved with the device viZaar shall no...

Страница 6: ...ced life threatening explosion and to a fire in the plant The operator is obliged to check the plant for substances vulnerable to explosion or fire before every new start up of the device Warning Neve...

Страница 7: ...arthed properly in case of an electrified application in relationship to the ground If impossible connect the system to the application or the ground depending on which one the user needs to touch The...

Страница 8: ...wers This short guide helps you to work with the es sential features of the system and to find the full operating instructions as E Reader on your de vice Additionally please find the full operating i...

Страница 9: ...1 1 Specifications 03 1 1 2 Control unit 04 1 3 1 Hardware setup 06 1 3 2 The control unit 06 1 3 3 User setup menu 07 1 2 Accessories 05 1 3 Quick reference initial setup and operation 06 1 4 1 Save...

Страница 10: ...ontainer for possible transport damages Dimensions H 540 x W 290 x D 400 mm PE Weight empty 9 26 kg Weight incl control unit 1 3 kg and power supply unit 2 2 kg 10 7 kg 01 www vizaar com 1 Carry handl...

Страница 11: ...it 1 Main power in 2 Main power switch 3 Audio in 4 Audio out 5 12V DC out 6 VGA ext Monitor out 7 Remote control 8 Reset button 9 Connector for INVIZ products 10 Video S Video In 11 Control unit lock...

Страница 12: ...ent for text and background Customizable color reference charts Enables free positioning of picture settings Up to 9 password protected user accounts with indivi dual configurations Multi lingual user...

Страница 13: ...y menu except setup B Capture single image Freeze unfreeze Start stop video recording 3 Slight control button light control 4 Slight control RF Remote Focus patented all distance Remote Focus 5 Batter...

Страница 14: ...tional INVIZ SNK INVIZ Revolver 80 pack 12 Optional camera head case 13 Optional INVIZ SNK pant tilt zoom camera 14 Optional INVIZ Revolver 80 endless rotation camera 15 Centring ring small 16 Accesso...

Страница 15: ...he power supply unit optional battery pack 4 Fix the pack by mounting the pins back into its position 1 3 2 The control unit 3 Release control unit lift latch The control unit with the integrated touc...

Страница 16: ...tomatic only INVIZ products see page 04 The red slide bar offers the patented Remote Focus see page 04 Sliding up or down will bring your image into perfect focus B Starting with the INVIZ SNK INVIZ...

Страница 17: ...off your system of return to operation For further shutdown instructions and backup in stallation after system breakdowns please refer to 3 7 System backup and shutdown on page 36 only in full operati...

Страница 18: ...www vizaar com 2 Tips questions and solutions 09 2 1 Tips for your operations with the INVIZ MATRIX 09 2 2 Problems and system warnings 10 2 1 1 After the initial start up 09 2 1 2 General tips 09...

Страница 19: ...tion can be activated e g remote control valves turbine rotors agitators etc For achieving meaningful inspection results the application ought to be cleaned in advance as long as depositions need not...

Страница 20: ...on Set back all image configuration see page 13 The system doesn t respond anymore If your system doesn t respond turn the main switch off and start it again by turning the main switch on The system s...

Страница 21: ...Affix Affix www vizaar com...

Страница 22: ...evolver 80 INVIZ BIG INVIZ Pipe This device possesses CE identification and ful fills the conformity with standardisation EN 50081 2 EN 50082 2 EN 55022 The fulfillment of this standard presupposes th...

Страница 23: ...ments in all aspects of our business This is an ongoing process involving all staff and processes guided and certified by experts Furthermore our personal commitment to qua lity is attached to your IN...

Отзывы: