background image

7

4

While looking into the eyepiece of the polar 
alignment scope, adjust the direction of the 

mount by turning the altitude adjustment 
bolt and azimuth adjustment knobs so that 
Polaris comes as close as possible to the 
designated position on the reticle.

Set Polaris to the gap between the two segments of the lines 
marked 2014 and 2040 adjacent to a mark “POLARIS” as shown 
in the figure.

5

As Polaris shifts to the designated position on the reticle, both 
Delta UMi and 51 Cep come close to their own designated 
position scales respectively. While looking into the eyepiece of the 
polar alignment scope, turn the polar alignment scope body so 
that each of the position scale for Delta UMi and 51 Cep come to 
the closest to actual Delta UMi and 51 Cep respectively.

The numbers 15 and 40 on the position scales for Delta UMi and 
51 Cep show the years 2014 and 2040 respectively.

 Celestial north

★ 

Celestial north

Azimuth adjustment knob

Altitude adjustment bolt

Polaris

Delta UMI

51 Cep

Содержание 4955295355327

Страница 1: ...Instruction Manual for PF L II Polar Alignment Scope...

Страница 2: ...e sure to dispose of your used batteries as required by law at a local collection point or in the retail market Disposal in domestic waste violates the Battery Directive Batteries that contain toxins...

Страница 3: ...adjusting dial of the polar alignment scope Pushing the switch will illuminate the polar alignment reticle in red light The red light becomes dimmer gradually after a certain interval of illumination...

Страница 4: ...brightness adjusting dial by turning it counterclockwise 2Turn the battery compartment on the polar alignment scope downward as shown in the figure so that the old battery can fall out of from the ba...

Страница 5: ...le with the designated 3 stars seen in the polar alignment scope Also the patterns of the Big Dipper and Cassiopeia are engraved on the reticle for use as a guidepost for the North Pole 1 Check your o...

Страница 6: ...ope Real field of view in the northern sky Big Dipper Cassiopeia Real field of view in the northern sky The patterns of the Big Dipper and Cassiopeia on the reticle are positioned to correspond to the...

Страница 7: ...s Polaris shifts to the designated position on the reticle both Delta UMi and 51 Cep come close to their own designated position scales respectively While looking into the eyepiece of the polar alignm...

Страница 8: ...the lines Polaris is out of place from the designated position This is part of the process Adjust the red light illumination to be dimmer if the reticle is too bright to see the 4th magnitude Delta U...

Страница 9: ...designated position scales respectively Tighten the azimuth adjustment knobs at both sides to finish the polar alignment As an illustration here Polaris is set to the edge of the line on the side of 2...

Страница 10: ...each of the position scale on the reticle with the designated 3 stars caught by the polar alignment scope Also the pattern of the Southern Cross and Alpha Eridani are engraved on the reticle for use a...

Страница 11: ...in the field of view of the polar alignment scope Both the Southern Cross and Alpha Eridani on the reticle are positioned to correspond to the real sky They are used as a guidepost to know the turning...

Страница 12: ...k Oct as shown in the figure 5 As Sigma Octantis shifts to the designated position on the reticle both Tau Octantis and Chi Octantis come close to their own designated position scales respectively Whi...

Страница 13: ...position from the gap between the lines Adjust the red light illumination to be dimmer if the reticle is too bright to see the 5th magnitude stars Sigma and Tau Celestial south Celestial south Center...

Страница 14: ...lignment As an illustration here Sigma Octantis is set to the edge of the line on the side of 2014 and both Tau and Chi Octantis are set to the middle of the curved lines of the position scale at the...

Страница 15: ...ellanic Cloud and Beta Crux and divide it at a ratio of one to two You will find the four stars of Octans at the divide 2 Directing to the Octans using the arrangement of stars in the Southern Cross C...

Страница 16: ...VIXEN European Distributor Bresser GmbH Gutenbergstrasse 2 D 46414 Rhede Germany Phone 49 0 2872 80 740 E Mail info bresser de www bresser de Manual_X000327_PS L II Polsucher_en_Vixen_122021 indd...

Отзывы: