background image

2

Hereby, Bresser GmbH declares that the equipment type with part number: X000327 is in compliance with Directive: 2014/53/EU. 

The full text of the EU declaration of conformity is available at the following internet address:  

www.bresser.de/download/X000327/CE/X000327_CE.pdf

Bresser UK Ltd. has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. 

The full text of the UKCA declaration of conformity is available at the following internet address:  

www.bresser.de/download/X000327/UKCA/X000327_UKCA.pdf

Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain

Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or 
environmental authority for information on the proper disposal.

 Do not dispose of electronic devices in the household garbage! As per the Directive 2002/96/EC of the European Parliament on waste electrical 
and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an 
environmentally friendly manner.

 In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly 
forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in 
domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol.

Cd¹

Hg²

Pb³

1

 battery contains cadmium

2

 battery contains mercury 

3

 battery contains lead

Read the safety instructions and the operating instructions carefully before using the appliance.

Keep these operating instructions in a safe place for future reference. If the appliance is sold or passed on, the operating instructions must be 

passed on to any subsequent owner/user of the product.

Respect the privacy of those around you - do not look into flats with this device, for example!

DANGER of bodily injury

Never look directly at or near the sun with this unit. There is a DANGER OF BLINDNESS!

Children may only use the unit under supervision. Keep packaging materials (plastic bags, rubber bands, etc.) away from children! 

There is a DANGER OF CHOKING!

Not suitable for children under 3 years!

RISK OF FIRE

Do not expose the unit - especially the lenses - to direct sunlight! The light bundling could cause fires.

Do not expose the unit to temperatures above 60 °C!

Warranty & Service

The regular warranty period is 2 years and starts on the day of purchase. The complete warranty conditions as well as information on warranty 
extensions and services can be found at: 

  www.bresser.de/warranty_terms

Allgemeine Warnhinweise

EC DECLARATION OF CONFORMITY

UKCA DECLARATION OF CONFORMITY

Entsorgung

Содержание 4955295355327

Страница 1: ...Instruction Manual for PF L II Polar Alignment Scope...

Страница 2: ...e sure to dispose of your used batteries as required by law at a local collection point or in the retail market Disposal in domestic waste violates the Battery Directive Batteries that contain toxins...

Страница 3: ...adjusting dial of the polar alignment scope Pushing the switch will illuminate the polar alignment reticle in red light The red light becomes dimmer gradually after a certain interval of illumination...

Страница 4: ...brightness adjusting dial by turning it counterclockwise 2Turn the battery compartment on the polar alignment scope downward as shown in the figure so that the old battery can fall out of from the ba...

Страница 5: ...le with the designated 3 stars seen in the polar alignment scope Also the patterns of the Big Dipper and Cassiopeia are engraved on the reticle for use as a guidepost for the North Pole 1 Check your o...

Страница 6: ...ope Real field of view in the northern sky Big Dipper Cassiopeia Real field of view in the northern sky The patterns of the Big Dipper and Cassiopeia on the reticle are positioned to correspond to the...

Страница 7: ...s Polaris shifts to the designated position on the reticle both Delta UMi and 51 Cep come close to their own designated position scales respectively While looking into the eyepiece of the polar alignm...

Страница 8: ...the lines Polaris is out of place from the designated position This is part of the process Adjust the red light illumination to be dimmer if the reticle is too bright to see the 4th magnitude Delta U...

Страница 9: ...designated position scales respectively Tighten the azimuth adjustment knobs at both sides to finish the polar alignment As an illustration here Polaris is set to the edge of the line on the side of 2...

Страница 10: ...each of the position scale on the reticle with the designated 3 stars caught by the polar alignment scope Also the pattern of the Southern Cross and Alpha Eridani are engraved on the reticle for use a...

Страница 11: ...in the field of view of the polar alignment scope Both the Southern Cross and Alpha Eridani on the reticle are positioned to correspond to the real sky They are used as a guidepost to know the turning...

Страница 12: ...k Oct as shown in the figure 5 As Sigma Octantis shifts to the designated position on the reticle both Tau Octantis and Chi Octantis come close to their own designated position scales respectively Whi...

Страница 13: ...position from the gap between the lines Adjust the red light illumination to be dimmer if the reticle is too bright to see the 5th magnitude stars Sigma and Tau Celestial south Celestial south Center...

Страница 14: ...lignment As an illustration here Sigma Octantis is set to the edge of the line on the side of 2014 and both Tau and Chi Octantis are set to the middle of the curved lines of the position scale at the...

Страница 15: ...ellanic Cloud and Beta Crux and divide it at a ratio of one to two You will find the four stars of Octans at the divide 2 Directing to the Octans using the arrangement of stars in the Southern Cross C...

Страница 16: ...VIXEN European Distributor Bresser GmbH Gutenbergstrasse 2 D 46414 Rhede Germany Phone 49 0 2872 80 740 E Mail info bresser de www bresser de Manual_X000327_PS L II Polsucher_en_Vixen_122021 indd...

Отзывы: