VIVOTEK
User's Manual - 193
di
0~15
1
6/6
Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin
0~7
0
6/6
Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0
0~7
0
6/6
Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
valevel
<boolean>
0
6/6
Enable/Disable audio detect.
valevel0
<boolean>
0
6/6
Enable/Disable audio detect profile.
vi
0~7
0
6/6
Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
inter
1~999
1
6/6
Interval of snapshots in minutes.
This field is used when trigger
condition is “seq”.
weekday
0~127
127
6/6
Indicate which weekday is scheduled.
One bit represents one weekday.
bit0 (LSB) = Saturday
bit1 = Friday
bit2 = Thursday
bit3 = Wednesday
bit4 = Tuesday
bit5 = Monday
bit6 = Sunday
For example, to detect events on
Friday and Sunday, set weekday as
66.
begintime
hh:mm
00:00
6/6
Begin time of the weekly schedule.
Содержание SD8364E/ -M