VIVOTEK
218 - User's Manual
7.2 status
Group: status
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
di_i<0~(ndi-1)>
<product dependent>
<boolean>
0
1/7
0 => Inactive, normal
1 => Active, triggered
(capability.ndi > 0)
do_i<0~(ndo-1)>
<product dependent>
<boolean>
0
1/7
0 => Inactive, normal
1 => Active, triggered
(capability.ndo > 0)
onlinenum_rtsp
integer
0
6/7
Current number of RTSP
connections.
onlinenum_httppush
integer
0
6/7
Current number of HTTP push
server connections.
eth_i0
<string> <product
dependent>
1/7
Get network information from
mii-tool.
vi_i<0~(nvi-1)>
<product dependent>
<boolean>
0
1/7
Virtual input
0 => Inactive
1 => Active
(capability.nvi > 0)
7.3 digital input behavior define
Group: di_i<0~(ndi-1)>
(capability.ndi > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high
1/1
Indicates open circuit or closed
circuit (inactive status)
7.4 digital output behavior define
Group: do_i<0~(ndo-1)>
(capability.ndo > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
open
1/1
Indicate open circuit or closed
circuit (inactive status)