VIVOTEK
24 - User's Manual
1. The DO+ pin provides a 5V output, and the max. load is 50mA.
2. The max. voltage for DO- pins is 30VDC (External power).
In order to control AC devices, the following diagram can be taken into consideration.
This diagram uses a relay to control the ON/OFF condition of the AC device.
3. An external relay can be triggered by using the DO+ or by an external power source,
depending on the type of relay you use.
4. In case of using an individual relay (instead of using a relay module), for protection
against voltage or current spikes, a transient voltage suppression diode must be
connected in parallel with the inductive load.
DI-
DO+
DI+
DO-
Switch
External Device
External DC power
Dry contact with external DC power source to supply a relay. Dry contact is the safest connec
ti
on
to protect devices.
NC
NO
Relay
Photo
Coupler
DC
DC 0V
DC 0V
External AC power
with Protected Earth
AC
PE
PE
DI/DO Diagram
Содержание MD9560-DH
Страница 6: ...VIVOTEK 6 User s Manual Dimension Drawing...
Страница 19: ...VIVOTEK User s Manual 19 13 With a live video you can adjust the camera lens tilt or totation angle 90 90...
Страница 90: ...VIVOTEK 90 User s Manual...
Страница 182: ...VIVOTEK 182 User s Manual 2019 VIVOTEK INC All Right Reserved 51 NAME VALUE SECURITY get set DESCRIPTION re_mode 0...