VIVOTEK
User's Manual - 157
7.3digital input behavior define
Group:
di_i<0~(n-1)>
for n is the value of "capability_ndi"
(capability.ndi > 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
1/1
Indicates open circuit or closed circuit
(inactive status)
7.4digital output behavior define
Group:
do_i<0~(n-1)>
for n is the value of "capability_ndo"
(capability.ndo > 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
1/1
Indicate open circuit or closed circuit
(inactive status)
7.5security
Group:
security
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
privilege_do
view, operator,
admin
1/6
Indicate which privileges and above can
control digital output
(capability.ndo > 0)
privilege_camctrl
view, operator,
admin
1/6
Indicate which privileges and above can
control PTZ
(capability.ptzenabled > 0 or capability.eptz
> 0)
user_i0_name
string[64]
6/7
User name of root
user_i<1~20>_name
string[64]
6/7
User name
user_i0_pass
password[64]
7/6
Root password
user_i<1~20>_pass
password[64]
7/6
User password
user_i0_privilege view,
operator,
admin
6/7
Root privilege
user_i<1~20>_ privilege
view,
operator,
admin
6/6
User privilege
Содержание CC8371-HV
Страница 82: ...VIVOTEK 82 User s Manual...