Diagnostic
Page
In
the
diagnostics
page,
you
can
find
important
system
operating
information.
System
power
on
time
(hours)
System
power
on
time
records
total
the
accumulated
number
of
operating
hours.
LED
power
on
time
(hours)
LED
power
on
time
as
the
total
LED
ON
hours.
Inputs
The
Input
state
reports
the
input
voltage
of
power
supply
to
CaMate.
It
records
the
Max.
and
Min.
voltage
ever
recorded,
the
average
voltage
during
operation,
and
the
current
voltage
reading.
The
Out
of
range
count
records
the
event
when
the
input
voltage
is
under
DC12V
‐
10%
(DC10.8V)
or
over
the
AC24V+10%
(AC26.4V).
LED
Voltage
The
LED
voltage
reports
the
health
condition
for
LED
strings,
as
there
are
4
LED
strings
in
CaMate.
The
normal
LED
ON
voltage
should
fall
between
400mV
and
1200mV.
The
Over
range
count
records
the
event
when
the
detected
LED
voltage
is
over
1200mV.
Once
the
LED
voltage
is
over
range,
the
LED
is
probably
damaged.
The
4
LED
strings
work
independently.
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
14