User Manual rev. 1.1. Aug. 2015
105
The number of BPDU's a bridge port can send per second. When exceeded,
transmission of the next BPDU will be delayed. Valid values are in the range 1 to
10 BPDU's per second.
Advanced Settings
Edge Port BPDU Filtering :
Control whether a port explicitly configured as Edge will transmit and receive
BPDUs.
Edge Port BPDU Guard :
Control whether a port explicitly configured as Edge will disable itself upon
reception of a BPDU. The port will enter the error-disabled state, and will be
removed from the active topology.
Port Error Recovery :
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and
re-enabled for normal STP operation. The condition is also cleared by a system
reboot.
Port Error Recovery Timeout :
The time to pass before a port in the error-disabled state can be enabled. Valid
values are between 30 and 86400 seconds (24 hours).
Buttons
Apply – Click to save changes.
Reset- Click to undo any changes made locally and revert to previously saved
values.
Содержание AW-GEV-104A Series
Страница 66: ...User Manual rev 1 1 Aug 2015 66...
Страница 137: ...User Manual rev 1 1 Aug 2015 137 values...
Страница 183: ...User Manual rev 1 1 Aug 2015 183 values...
Страница 195: ...User Manual rev 1 1 Aug 2015 195 Clear Clears the counters for all ports...
Страница 236: ...User Manual rev 1 1 Aug 2015 236 Updates the table starting with the entry after the last entry currently displayed...
Страница 241: ...User Manual rev 1 1 Aug 2015 241 Refresh Click to refresh the page...
Страница 317: ...User Manual rev 1 1 Aug 2015 317 Note that if using IE browser you can only export in the SVG format...