background image

3

English

II

Swivel Positions and Directions

460.0 mm(18.11")

(14.56")

(6.77")

(6.43")

(6.08")

(15.79")

370.0 mm

401.1 mm

172.0 mm

163.5 mm

154.5 mm

(9.64")

(3.46")

88.0 mm

245.0 mm

(3.38")

86.0 mm

460.0 mm(18.11")

130.4 mm(5.13")

119.9 mm

(4.72")

(14.56")

(6.77")

(1.17")

(15.79")

370.0 mm

401.1 mm

172.0 mm

29.9 mm

(9.54")

242.5 mm

(3.62")

(5.88")

(2.97")

92.0 mm

149.5 mm

75.7 mm

(9.64")

(3.46")

88.0 mm

245.0 mm

(13.62")

346.0 mm

(14.09")

358.0 mm

(2.71")

69.0 mm

Dimensions 

Содержание AE-510

Страница 1: ...Quick Installation Guide Stainless Steel Housing Series Rev 1 0 ...

Страница 2: ... Net Weight 7 5kg 8kg Cable Grants PG16 x 2 PG16 x 2 UNPACKING Unpack carefully Electronic components can be damaged if improperly handled or dropped If an item appears damaged in shipment place it properly in its carton and notify the shipper IMPORTANT 1 Read and follow Instructions All operating and user instructions should be read and followed before the unit is to be operated connections If yo...

Страница 3: ...mm 172 0 mm 163 5 mm 154 5 mm 9 64 3 46 88 0 mm 245 0 mm 3 38 86 0 mm 460 0 mm 18 11 130 4 mm 5 13 119 9 mm 4 72 14 56 6 77 1 17 15 79 370 0 mm 401 1 mm 172 0 mm 29 9 mm 9 54 242 5 mm 3 62 5 88 2 97 92 0 mm 149 5 mm 75 7 mm 9 64 3 46 88 0 mm 245 0 mm 13 62 346 0 mm 14 09 358 0 mm 2 71 69 0 mm Dimensions ...

Страница 4: ...11 130 4 mm 5 13 119 9 mm 4 72 14 56 6 77 1 17 15 79 370 0 mm 401 1 mm 172 0 mm 29 9 mm 9 54 242 5 mm 3 62 5 88 2 97 92 0 mm 149 5 mm 75 7 mm Dimensions with the IR unit and wiper Camera Mounting Platform 24VAC Power distribution board AE 510 ...

Страница 5: ...5 English Camera Mounting Platform 24VAC Power distribution board AE 510 I Wiper VAIR module Terminal block ...

Страница 6: ...r of Infrared protection glasses when working with the product Always use camera live view to oberve IR lighting effects WARNING 1 How to open the housing Slide out the rear cover plate of the housing taking care to leave the sealing washer in its seating Heater or wiper or VAIR connect need unplug AE 510 Heater Connect Unplug AE 510 I Heater Connect VAIR Connect Unplug ...

Страница 7: ... 2 3 4 5 6 7 8 o white orange stripe O orange solid g white green stripe B blue solid b white blue stripe G green solid br white brown stripe BR brown solid You may need to remove the RJ45 connector and use a crimping tool to connect the Ethernet wires to an RJ45 connector inside the enclosure Use an Ethernet cable of the width of 5 6 5mm 3 When done tighten up and install the waterproof connector...

Страница 8: ... to the bottom of the camera the label side using the included screw 5 Connect 24V power source to the power input terminal Connect power wires from the DC 12V output to the camera Below is the distribution board drawing power from 24V AC AE 510 DC 12V OUT to camera AC 24V OUT AC 24V IN AE 510 ...

Страница 9: ...minal block Facing the rear side of the housing from left to right DO2 Connect to tank water pump DI2 Wiper control connects to IP camera s DO for manually triggering washer RS485 RS485 RS485 can be used to control IR illuminator beam angles etc RS485 RS485 DO 5V VCC DI GND DO1 IR LED status DI1 IR control synchronizes day night mode switching for IP camera It is related to IR ...

Страница 10: ...10 beam angle for different effective illumination range VAIR 12W 6W no of LEDs 2P 2P Beam angle 10 20 30 40 10 20 30 40 Distance meter 140m 110m 80m 50m 100m 80m 60m 40m DIP Switch LL LH HL HH ...

Страница 11: ...DI2 DI RS485 RS485 DO1 DI1 DO Tank ctrl Wiper ctrl GND IR LED IR ctrl 5V VCC Camera Terminal Block Enclosure Terminal Block 2 IR control by RS485 command DO DO DI1 DI2 DI3 DI RS485 RS485 AC DC pwr AC DC pwr AWG20 AWG26 AC24V DO2 DI2 DI RS485 RS485 DO1 DI1 DO DC12V Tank ctrl Wiper ctrl GND IR LED IR ctrl 5V VCC Camera Terminal Block Enclosure Terminal Block Note the wire gauge requirements for maki...

Страница 12: ...nal Block Below is a diagram for water tank and wiper control The wiper can be started by manually triggering the Digital Output from the camera user interface 3 IR control by Camera DO Camera will automatically trigger IR light on off via DO DO DO DI1 DI2 DI3 DI RS485 RS485 AC DC pwr AC DC pwr AWG26 DO2 DI2 DI RS485 RS485 DO1 DI1 DO Tank ctrl Wiper ctrl GND IR LED IR ctrl 5V VCC Camera Terminal B...

Страница 13: ...et mounting type of installation plug heater or wiper or VAIR connector to power board 7 Before closing the housing reinsert the bottom orientating the slide according to the installation required on the wall bracket or on the Pan tilt head for the right camera The front end of the slider is about 70mm from the window Please install the camera in the appropriate position 70mm ...

Страница 14: ...14 9 The housing can also be installed using the pole mount or corner mount Stainless Steel Camera Housing Pole Mount CornerMount Stainless Steel Camera Housing 8 Sunshield mounting ...

Страница 15: ...5 English 10 Open a web console with the camera Use the Media Focus function to tune for a best image focus on your target area If preferred e g shooting fast moving vehicles select the 60fps frame rate ...

Страница 16: ...e check if the input signals are correctly detected You may simulate the night mode by blocking the IR unit s light sensor Change the triggering parameters when necessary synchronized with the digital input you connected ...

Страница 17: ...1 Pelco D Zoom Wide VaIR Lens Tele FF 01 00 20 00 00 21 Pelco D Zoom Tele Wiper On FF 01 00 09 00 01 0B Pelco D Aux 1 On Wiper Off FF 01 00 0B 00 01 0D Pelco D Aux 1 Off Wiper and Washer On FF 01 00 09 00 02 0C Pelco D Aux 2 On Wiper and Washer Off FF 01 00 0B 00 02 0E Pelco D Aux 2 Off IR Led Force On FF 01 00 09 00 03 0D Pelco D Aux 3 On IR Led Force Off FF 01 00 0B 00 03 0F Pelco D Aux 3 Off Co...

Страница 18: ...L Lux changes is made by every10Lux For example LightSensorGate 100 FF 01 00 18 03 0A 26 LightSensorGate 200 FF 01 00 18 03 14 30 The parameters of IR illuminator can be controlled via the RS485 connection You can enable the connection in PTZ Mechanical window Select the defaults for the IR illuminator Pelco D baud rate 2400 Data bits 8 Stop bit 1 Parity none Defaults for IR Pelco D 2400 8 1 none ...

Страница 19: ...rounded via MOSFET DI connected LED Off DO_1 no input VaIR Lens Zoom control Dip Switch When Lens stops its last position will be memoried and when powered on again lens will move to the Wiper Wahser control DI_2 Trigger When DI_2 connected to DI Low wiper and washer operate for 3 times and then stop Using RS485 Command Wiper Only Pelco D Aux 1 On Off Wiper On wiper takes action Wiper Off wiper st...

Страница 20: ...20 This page is intentionally left blank ...

Отзывы: