background image

17

English

Use the included M10 hex socket screws to secure the power box to a pole-mount or corner mount 

bracket. 

M10

3/4” conduit

AM-314

AM-315

AM-414

AM-21D

AM-21E

Box:

AA-351

AA-352

AM-718

Outdoor PoE switch:

AW-GEU-083A-240

AW-GET-083A-120

AW-GET-123A-240

AW-GEU-086A-240

AW-GET-086A-120

AW-GET-126A-240

Speed Dome:

SD9361/62/63/64/65/66

SD83xx

AM-212/221/220/21C

The mounting hole definition is illustrated below. The same mounting hole pattern apply to all pole-

mount and corner-mount brackets. 

Содержание AE-238

Страница 1: ...de AE Series Rev 1 0 Outdoor Housing Ordering part no AE 238 900041100G AE 239 900041200G AE 243 900041900G AE 244 900042400G AE 23A 900042300G AE 23B 900042200G AE 23C 900041700G AE 23D 900041800G AE 23E 900041600G AE 23F 900042100G ...

Страница 2: ...r coating White epoxy powder coating White epoxy powder coating Dimensions 415 L x 170 W x 125 H mm 502 8 L x 170 W x 135 5 H mm 415 L x 170 W x 125 H mm IR not included 502 8 L x 170 W x 135 5 H mm IR not included Net Weight 2 2kg 4 84 lb 2 7kg 5 95 lb 2 8kg 6 18 lb wiper model 2 2kg 4 85 lb 2 7kg 5 95 lb 2 8kg 6 18 lb wiper model UNPACKING Unpack carefully Electronic components can be damaged if...

Страница 3: ...ions 415 mm 125 mm 170 mm 400 mm 255 mm USABLE AREA 105 mm 77 4 mm USABLE AREA 105 mm 502 8 mm 135 5 mm 158 5 mm 170 mm 400 mm 77 4 mm USABLE AREA 255 mm USABLE AREA AE 238 AE 239 AE 23A 23B 23C 23D 23E 23F 415 mm 206 9 mm 170 mm 400 mm 135 mm 88 05 mm 87 01 mm AE 243 AE 244 ...

Страница 4: ... Platform M16 1 2 Waterproof cable glands AC DC or PoE Power distribution board Ventilation fan Window frame heater coil 217 4 mm 502 8 mm 417 mm 135 mm 88 05 mm 87 01 mm 95 R 9 6 5 95 95 R96 45 Dimensions with the IR unit and wiper VAIR module ...

Страница 5: ...lluminator Please avoid eye exposure or apply appropriate protection such as wearing a pair of Infrared protection glasses when working with the product Always use camera live view to oberve IR lighting effects WARNING Ethernet cable Ø4 6 5mm Power wires DI DO wires a combo cable from IR illuminator if applied Note that some cables are connected when shipped You do not need to connect heater blowe...

Страница 6: ... to remove the RJ45 connector and use a crimping tool to connect the Ethernet wires to an RJ45 connector inside the enclosure Use an Ethernet cable of the width of 5 6 5mm 2 When done tighten up and install the waterproof connectors 3 Assemble the camera components e g the CS ring and lens module Secure the mounting plate to the bottom of the camera the label side using the included screw ...

Страница 7: ...ousing 5 Connect 24V power source to the power input terminal Connect power wires from the DC 12V output to the camera You may also connect the 24V power to drive an external IRs Below is the distribution board drawing power from 24V AC DC Heater Blower IR angle selector I O terminal block Camera heater 24V AC DC IN 12V DC OUT 24V AC DC OUT Connectors to the front IR Power LED AE 23A AE 23B AE 23C...

Страница 8: ...ering washer DI2 Wiper control RS485 RS485 RS485 can be used to control IR illuminator beam angles etc RS485 RS485 DO 5V VCC DI GND DO1 IR LED status DI1 IR control synchronizes day night mode switching for IP camera It is related to IR cut filter AE 238 AE 243 DC 12V OUT to camera AC 24V OUT to external IR AC 24V IN Ground for IR LED AC 24V OUT to camera AC 24V IN AE 238 AE 243 ...

Страница 9: ...amera heater PoE OUT I O terminal block The PoE version housings have the same terminal pinouts with that of the 24V power source models DO2 Tank water pump control connects to IP camera s DO for manually triggering washer DI2 Wiper control RS485 RS485 RS485 can be used to control IR illuminator beam angles etc RS485 RS485 DO 5V VCC DI GND DO1 IR LED status DI1 IR control synchronizes day night mo...

Страница 10: ...control Below are the parameters of the IR illuminator Use the onboard jumpers to configure the beam angle for different effective illumination range VAIR 48W 24W 12W no of LEDs 18P Dual 18P 36mil Single 18P 30mil Single Beam angle 10 20 25 30 10 20 25 30 10 20 25 30 Distance meter 200m 180m 150m 120m 160m 140m 110m 80m 120m 100m 90m 60m VAIR 6W no of LEDs 4P 42mil Single Beam angle 10 20 30 40 Di...

Страница 11: ...O1 DI1 DO DC12V Tank ctrl Wiper ctrl GND IR LED IR ctrl 5V VCC Tank ctrl Tank low water GND Tank w pump A sample connection diagram consisting of a housing with IR illuminators and the IP816A camera is shown below Please refer to your camera s documentation if your camera comes with different pinouts AC DC 24V IN 1 Pump motor ON OFF 2 GND 3 Water level detector Low high 4 GND pin 1 pin 1 1 Water t...

Страница 12: ...D IR LED IR ctrl 5V VCC Tank ctrl Tank low water GND Below is a diagram using wiper control The wiper can be started by manually triggering the Digital Output from the camera user interface Note the wire gauge requirements for making the power connections For 24VAC 24W load Wire Gauge 22 20 18 16 14 12 Distance 55 90 150 230 270 600 feet ...

Страница 13: ...acket secure the intersection bracket to the bottom of the housing by driving two screws AM 11F AM 811 AM 21D AM 21E Below are the mounting hole dimensions for the mounting brackets Chances are you may need to plan for the locations of the brackets ...

Страница 14: ...ed below x2 thread Safety tether wire 8 Install the housing to the wall mount bracket by aiming and pressing the spring mortise and hook the bracket onto the groove in the spring mortise Secure the T30 anti tamper screws on the other side using the included L wrench Connect the included safety wire between enclosure and bracket ...

Страница 15: ...M 11E F and AM 811 pendant brackets use the two mounting holes as indicated below AM 21D AM 11E F AM 811 Another two mounting holes in the front can be used use an IR bracket AM 219 The bracket can be used to install external IRs AM 219 ...

Страница 16: ...r mount options along with a power box AA 351 AA 352 outdoor PoE switch or junction box CaMate IR illuminators If external IRs are installed you can contact VIVOTEK for a different type of waterproof connectors for the 1 2 conduits You can then route two of the conduits through the opening in the front of the bracket to the corresponding connectors on the IR illuminators The 24V power wires to the...

Страница 17: ... 414 AM 21D AM 21E Box AA 351 AA 352 AM 718 Outdoor PoE switch AW GEU 083A 240 AW GET 083A 120 AW GET 123A 240 AW GEU 086A 240 AW GET 086A 120 AW GET 126A 240 Speed Dome SD9361 62 63 64 65 66 SD83xx AM 212 221 220 21C The mounting hole definition is illustrated below The same mounting hole pattern apply to all pole mount and corner mount brackets ...

Страница 18: ...positions for the camera housings via AM 21D and AM 21E 10 If an IR illuminator is preferred remove the metal cover from underneath the housing Install the IR unit AI 106 107 108 109 by fastening 4 T30 anti tamper screws Note that the bubber gasket should be in place when you install the unit ...

Страница 19: ...rmware configurable options Open a web console with the camera Use the Media Focus function to tune for a best image focus on your target area If preferred e g shooting fast moving vehicles select the 60fps frame rate ...

Страница 20: ...cted You may simulate the night mode by blocking the IR unit s light sensor Change the triggering parameters when necessary Make sure that external IR is turned on in the night mode and that the IR cut filter option is synchronized with the digital input you connected ...

Страница 21: ...0 41 Pelco D Zoom Wide VaIR Lens Tele FF 01 00 20 00 00 21 Pelco D Zoom Tele Wiper On FF 01 00 09 00 01 0B Pelco D Aux 1 On Wiper Off FF 01 00 0B 00 01 0D Pelco D Aux 1 Off Wiper and Washer On FF 01 00 09 00 02 0C Pelco D Aux 2 On Wiper and Washer Off FF 01 00 0B 00 02 0E Pelco D Aux 2 Off IR Led Force On FF 01 00 09 00 03 0D Pelco D Aux 3 On IR Led Force Off FF 01 00 0B 00 03 0F Pelco D Aux 3 Off...

Страница 22: ... Lux changes is made by every10Lux For example LightSensorGate 100 FF 01 00 18 03 0A 26 LightSensorGate 200 FF 01 00 18 03 14 30 The parameters of IR illuminator can be controlled via the RS485 connection You can enable the connection in Configuration PTZ Mechanical window Select the defaults for the IR illuminator Pelco D baud rate 2400 Data bits 8 Stop bit 1 Parity none Defaults for IR Pelco D 2...

Страница 23: ...Switch 4 configurations using the Dip Switch on the distribution board When Lens stops its last position will be memoried and when powered on again lens will move to the previous position When powered on for the first time Lens will follow the DIP switch configuration Wiper Wahser control DI_2 Trigger When DI_2 connected to DI Low wiper and washer operate for 3 times and then stop Using RS485 Comm...

Страница 24: ...24 This page is intentionally left blank ...

Отзывы: