10
The 30W PoE version does not support external washer kit.
RS485+
RS485+, RS485 can be used to control IR illuminator beam angles, etc.
RS485-
RS485-
DO+
+5V VCC
DI-
GND
DO1
Tank water pump control, connects to IP camera's DO for manually triggering
washer.
DI1
IR control
Below are the parameters of the IR illuminator. Use the onboard jumpers to configure the
beam angle for different effective illumination range.
VAIR
48W
24W
12W
no. of
LEDs
18P/Dual
18P/36mil Single
18P/ 30mil Single
Beam
angle
10
°
20
°
25
°
30
°
10
°
20
°
25
°
30
°
10
°
20
°
25
°
30
°
Distance
(meter)
200m 180m 150m 120m 160m 140m 110m 80m
120m 100m 90m
60m
VAIR
6W
no. of LEDs
4P/42mil Single
Beam angle
10
°
20
°
30
°
40
°
Distance (meter)
100m
80m
40m
15m
Configuring IR illuminator
Содержание AE-238