![Vivotek 4710469351747 Скачать руководство пользователя страница 370](http://html1.mh-extra.com/html/vivotek/4710469351747/4710469351747_user-manual_1040347370.webp)
VIVOTEK
370 - User's Manual
© 2020 VIVOTEK INC. All Right Reserved
222
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
The dwelling time of each patrol point,
separated by “,”
* only available when
capability_camctrl_c0_rs485=2
preset_i<0~(k-1)>_nam
e
string[40]
1/4
Name of the preset location.
preset_i<0~(k-1)>_
dwelling
0 ~ 999
1/4
The dwelling time of each preset
location
* only available when
capability_camctrl_c0_rs485=2
uart
0 ~ "
capability_nuar
t"-1
1/4
Select corresponding uart
(capability_nuart>0).
* only available when
capability_camctrl_c0_rs485=2
cameraid
0~255
1/4
Camera ID controlling external PTZ
camera.
isptz
0 ~ 2
1/4
0: disable PTZ commands.
1: enable PTZ commands with PTZ
driver.
2: enable PTZ commands with UART
tunnel.
* only available when
capability_camctrl_c0_rs485=2
disablemdonptz
<boolean>
1/4
Disable motion detection on PTZ
operation.
7.41
Camera PTZ Control (IZ Series)
Group:
camctrl_c<0~(n-1)>
for n channel products
(capability_camctrl_c0_zoommodule = 1 and
capability_camctrl_c0_buildinpt = 0)
n denotes the value of "capability_nvideoin" and k denotes the value of "capability_npreset"
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ccdtype
string[16]
6/7
(Internal used, read only)
motortype
string[16]
6/7
(Internal used, read only)
cameraid
0 ~ 255
1/4
Camera ID controlling external PTZ