7.Error Code
Error code
Instruction
Solution
ER1
Defect of motor1 connecting or Hoare
Checking the connect of motor 1
ER2
Defect of motor2 connecting or Hoare
Checking the connect of motor 2
ER3
Defect of motor3 connecting or Hoare
Checking the connect of motor 3
ER4
Default phase of motor 1
Checking the connect of motor 1
ER5
Default phase of motor 2
Checking the connect of motor 2
ER6
Default phase of motor 3
Checking the connect of motor 3
ER7
Locked-rotor or over heat of motor 1
Reset and reduce the table load
ER8
Locked-rotor or over heat of motor 2
Reset and reduce the table load
ER9
Locked-rotor or over heat of motor 3
Reset and reduce the table load
ERR
Controller hardware error
Change controller
E31
Power supply of controller less or over
Connect the power again
E34
Abnormal connecting of hand controller
Checking the connecting of hand controller
A01
Anti-collision of motor 1
Operate again
A02
Anti-collision of motor 1
Operate again
A03
Anti-collision of motor 1
Operate again
A08
Anti-collision of balancing apparatus
Operate again
E09
Table incline or deviation over 1 cm
Check lead screw in column
HOT
Over heat or continuous work over 2min
Wait 18mins