7.Error Code

Error code

Instruction

Solution

ER1

Defect of motor1 connecting or Hoare

Checking the connect of motor 1

ER2

Defect of motor2 connecting or Hoare

Checking the connect of motor 2

ER3

Defect of motor3 connecting or Hoare

Checking the connect of motor 3

ER4

Default phase of motor 1

Checking the connect of motor 1

ER5

Default phase of motor 2

Checking the connect of motor 2

ER6

Default phase of motor 3

Checking the connect of motor 3

ER7

Locked-rotor or over heat of motor 1

Reset and reduce the table load

ER8

Locked-rotor or over heat of motor 2

Reset and reduce the table load

ER9

Locked-rotor or over heat of motor 3

Reset and reduce the table load

ERR

Controller hardware error

Change controller

E31

Power supply of controller less or over

Connect the power again

E34

Abnormal connecting of hand controller

Checking the connecting of hand controller

A01

Anti-collision of motor 1

Operate again

A02

Anti-collision of motor 1

Operate again

A03

Anti-collision of motor 1

Operate again

A08

Anti-collision of balancing apparatus

Operate again

E09

Table incline or deviation over 1 cm

Check lead screw in column

HOT

Over heat or continuous work over 2min

Wait 18mins

Содержание CTT-D06

Страница 1: ...tructions Please record your serial number in the space provided below and retain this manual for future reference This will save you timemake assembly easier and prevent possible damage to your new Desk Assistance may be required for some assembly procedures Correct assembly is your responsibility ...

Страница 2: ...Specification 100V 240V 24V DC2 1A 2 4A 45 4Kg 100Ib 25mm 7 9in s 750mm 1250mm 29 4in 46 9in Input Voltage Output Voltage USB Output Max Load Capacity Speed Height Range ...

Страница 3: ...ns save method as following when run to specific position touch S button indicator will show S and the will flicker while touch 1 3 button save this position to 1 3 button If run to memory spot touch corresponding storage position 1 3 button The indicator will show corresponding position height then run to storage corresponding position height automatically During run any button can stop system 4 ...

Страница 4: ...Reset and reduce the table load ER8 Locked rotor or over heat of motor 2 Reset and reduce the table load ER9 Locked rotor or over heat of motor 3 Reset and reduce the table load ERR Controller hardware error Change controller E31 Power supply of controller less or over Connect the power again E34 Abnormal connecting of hand controller Checking the connecting of hand controller A01 Anti collision o...

Страница 5: ...S 1 2 3 3 Load Capacity 45 4kg 100lb Load Capacity 6 9kg 15 2lb ...

Страница 6: ...M6X1 8PCS 4PCS Table Foot Cabinet wheel Hex wrench Power line Desktop Frame 2PCS 4PCS 1PC 1PC 1PC 1PC 5 M6X45 Parts List ...

Страница 7: ...Step 1 Assemble desktop Step 2 Assemble desk foot M6X45 8pcs 1pc Hex wrench M6X15 8pcs 1pc Hex wrench ...

Страница 8: ...Cabinet wheel Step 3 Assemble Cabinet wheel 4pcs ...

Отзывы: