Shift Device Display

Hold "M" button for 2 seconds to shift device display. The desk frame height displays 73.0cm-122cm. The 

stand height displays 39.0cm-52.0cm.

Switch the Display from Centimeter to Inch

The preset measurement shown on the display is cm.  If you would like to change cm to inch, restart 

the system by unplugging for at least 5 seconds and plug back in, then press “T” for at least 3 seconds.  

The control panel will beep twice (beeps twice if changing to inch, and beeps once changing to cm) and 

change the displayed unit.  Repeat to switch back from inch to cm.

Sleep Mode

After resting for 1 minute, the screen will turn off to prevent accidental operation.  Touch the screen to exit 

sleep mode and operate the desk.

Collision Avoidance Settings

Press and hold the "M" and "T" buttons together for 5 seconds until you hear the control panel beep 

twice indicating you are in the Collision Avoidance Settings Mode. The screen of the control panel 

will display the current sensistivity level (level 3 by default). Press the up or down arrow to adjust the 

desired sensitivity level. When you are finished selecting the new level, press the "M" butto n to save the 

sensitivity level. The Collision Avoidance Settings Mode will automatically exit if there is no futher activity 

within 8 seconds. 

Note:

 You must press the "M" button within 8 seconds of selecting the new sensitivity 

level to save the new setting or the unit will revert to the previous setting level. 

Collision Avoidance Sensitivity Levels:

 0-5, 

Default: 

3

0: Turn off Collision Avoidance.

1-5: Sensitivity Setting - Level 1 is the lowest sensitivity and the level 5 is the highest sensitivity.

NOTES

• 

Self-protection function: The unit will enter a protective mode should the system operate in 
excess of 2 minutes with “HOT” on the controller display.  The system will return to normal 
operation after approximately 18 minutes.

• 

Over-current protection mode: While operating, should the load on the desk exceed rated 
specifications, the system will enter into over-current protection mode to protect the system 
from damage.  When this happens, the desk will move downward approximately 30mm and 
come to a stop with the current height displayed.

• 

Do NOT remove or reconnect power to reset the unit when in a protective or “HOT” state, as 
this may damage the electronics.

TROUBLESHOOTING

Error Code Description/Resolution

ER1

Overload in downward direction.  Disconnect and reconnect power.

ER2/HOT

Overheating in controller.  Wait 18 minutes to allow controller to cool.

ER3

Motor connection fault.  Reconnect motor and perform a desk reset.

ER5

ER6

RSR / RST

Desk weight limit exceeded. Decrease desk load before operating. If error appears after 

reducing weight, the AC adapter may need to be replaced.

Connection error between control panel and electric monitor arm cable. Reconnect the 

USB cable and the connecter. Ensure the USB cable is being routed away from the cable 

sleeve and outside the cable clip to avoid any interference. 

An error has occurred and entered reset mode for protection; complete reset process to 

clear error.

Failure to follow these instructions may result in property damage and/or personal injury.

Содержание STAND-E-102B

Страница 1: ... device or follow the link for helpful videos and specifications related to this product https vivo us com products stand e 102b SKU STAND E 102B Control Panel help vivo us com www vivo us com 309 278 5303 Chat live with an agent GET IN TOUCH Monday Friday from 7 00am 7 00pm CST 3 ...

Страница 2: ...process is complete Stand When the monitor stand height display is incorrect run it to the highest point 52 0cm and then lowest point 39 0cm the monitor stand will self adjust the height level Upward and Downward Movement Press and hold the up or down arrow until the desk reaches the desired height Timed Reminder Mode To set the timer press T The display will flash 0 5h representing 30 minutes Pre...

Страница 3: ...nce Sensitivity Levels 0 5 Default 3 0 Turn off Collision Avoidance 1 5 Sensitivity Setting Level 1 is the lowest sensitivity and the level 5 is the highest sensitivity NOTES Self protection function The unit will enter a protective mode should the system operate in excess of 2 minutes with HOT on the controller display The system will return to normal operation after approximately 18 minutes Over...

Страница 4: ...ensure you have a fully functioning product FOR MORE VIVO PRODUCTS CHECK OUT OUR WEBSITE AT www vivo us com help vivo us com AVG RESPONSE TIME within office hrs 1HR 8M 23 within 15m 38 within 30m 61 within 1hr 83 within 2hr 92 within 3hr Love your new VIVO setup and want to share Tag us in your photo vivo_us AVG RESOLUTION TIME within office hrs 15 M www vivo us com Chat live with an agent AVG RES...

Отзывы: