— 69—
A
PPENDIX
I
FOR DW770UST / DW771USTi
RS-232C Protocol
RS232 Setting
Baud rate:
9600
Parity
check:
None
Data bit:
8
Stop bit:
1
Flow
Control
None
Control Command Structure
Header code
Command code Data code
End code
HEX
h
Command
Data
0Dh
ASCII
‘V’
Command
Data
CR
Operation Command
Note:
"CR" mean Carriage Return
XX=00-98, projector's ID, XX=99 is for all projectors
Return Result P=Pass / F=Fail
n: 0:Disable/1: Enable/Value(0~9999)
Command Group 00
ASCII
HEX
Function
Description
Return
Result
VXXS0001
56h Xh Xh 53h 30h 30h 30h 31h 0Dh
Power On
P/F
VXXS0002
56h Xh Xh 53h 30h 30h 30h 32h 0Dh
Power Off
P/F
VXXS0003
56h Xh Xh 53h 30h 30h 30h 33h 0Dh
Resync
P/F
VXXG0004
56h Xh Xh 47h 30h 30h 30h 34h 0Dh
Get Lamp Hours
Pn/F
VXXS0006
56h Xh Xh 53h 30h 30h 30h 36h 0Dh
System Reset
P/F
VXXG0007
56h Xh Xh 47h 30h 30h 30h 37h 0Dh
Get System Status
0:Reset
1:Standby
2:Operation
3:Cooling
Pn/F
VXXG0008
56h Xh Xh 47h 30h 30h 30h 38h 0Dh
Get F/W Version
Pn/F
VXXS0010
56h Xh Xh 53h 30h 30h 31h 30h 0Dh
Lamp Hours Reset
P/F
Command Group 01
ASCII
HEX
Function
Description
Return
Value
VXXG0101
56h Xh Xh 47h 30h 31h 30h 31h 0Dh
Get Brightness
n=0~100
Pn/F
VXXS0101n 56h Xh Xh 53h 30h 31h 30h 31h nh 0Dh
Set Brightness
n=0~100
P/F
VXXG0102
56h Xh Xh 47h 30h 31h 30h 32h 0Dh
Get Contrast
n=0~100
Pn/F
VXXS0102n 56h Xh Xh 53h 30h 31h 30h 32h nh 0Dh
Set Contrast
n=0~100
P/F
VXXG0103
56h Xh Xh 47h 30h 31h 30h 33h 0Dh
Get Color
n=0~100
Pn/F
Содержание D77 Series
Страница 1: ...D77 Series ...
Страница 73: ... 65 Projector Dimensions DW771USTi DH773USTi 287 5mm 374 5mm 206 9mm 123 1mm ...
Страница 74: ... 66 Projector Dimensions DW770UST DH772UST 167 6mm 122 6mm 374 5mm 287 5mm ...
Страница 75: ... 67 Projector Dimensions DW771USTie DH773USTie 287 5mm 374 5mm 193 6mm 123 1mm ...