The Pandora360 comes in a wellboard box lined with specially cast plastic foam lining. 

Start by cutting the box sealing tape and take out the parts. Each box includes the following 
parts: 

 

One Pandora360 Node. 

 

One bag with Strain Relief parts, 

 

One bag with Gasket and plugs for complete weather proofing of the different cable 
connections. 

4.3. Installing 

The Pandora360 node is installed as follows: 

4.3.1. Pole Installation 

Pandora360 installer's Tools will direct the installer where the unit can be located on the roof 
(typically a polygon is defined). The unit will need to report it's correct GPS position back to the 
IT systems to verify the node is installed at the correct site. (If this is not verified the installer 
will not be able to complete the installation process.) This roof-top location should be a place 
close to the top of the roof that allows for line-of-sight to neighboring nodes as provided by the 
planning data. 

On the roof: 

1.

 

Mark the proper location for the pole as indicated by the Installer's Tool. 

2.

 

Check that line-of-site to adjacent Pandora360s are free. 

3.

 

Mount the foot and the pole on the roof so that the pole is truly vertical. (Make sure that 
the installation is done according to local regulations to prevent leaks etc.) 

4.

 

Mount the support struts for the pole. 

4.3.2. Cable Installation 

Use the following cable types for the installation: 

Connection 

Cable type/Part 

Number 

Name 

PoE & LAN 

ECB0012/xxx 

24 AWG  CAT5e outdoor SFTP (Shielded Foiled 
Twisted Pair) cable, black

Optical Fibre 
Cable 

ACC0004/xxx 

LC-LC Single mode 1310 nm with short fanout 
because of strain relief for outdoor use 

DC & I/O 

ECB0014/xxx 

(6x) 20 AWG shielded (foil and braid) 

Содержание Pandora360

Страница 1: ...1 1 Introduction 2 Radio Frequency Exposure 3 Directions for Use o 3 1 Preconditions o 3 2 Intended Use 4 Installation Procedure o 4 1 Tools for Installation o 4 2 Unpacking o 4 3 Installing 4 3 1 Pol...

Страница 2: ...are also available from the UPS in the same cable as the DC cable Operations and Maintenance is done via the LAN port or the or SFP port 802 11b g n is used for maintenance operations when a field te...

Страница 3: ...Page 3 of 15 Figure 2 Horizontal Radio Sectors on the Pandora360 Node...

Страница 4: ...lly and vertically are done electronically via software running on the Qualcomm baseband and RF chipset Figure 3 Vertical adjustment of the Pandora360 Radio Lobe The Pandora360 comes in two variants o...

Страница 5: ...ious in the environment and its WiFi management connection makes local management and maintenance from ground safe and easy for the maintenance personnel The device can be installed in meshes with at...

Страница 6: ...h will become the sole responsibility of the installer 3 2 Intended Use The Pandora360 is intended for outdoor use in broadband mesh configurations It is managed and maintained remotely using the Node...

Страница 7: ...ot be able to complete the installation process This roof top location should be a place close to the top of the roof that allows for line of sight to neighboring nodes as provided by the planning dat...

Страница 8: ...der 1 Start with the grounding GND cables make sure the grounding cable is properly terminated Fork lug for 4mm screw and well secured to the Earthing screw on the Strain Relief 2 Fit the Data cables...

Страница 9: ...ems On site an installer will scan the node label on the Pandora360 node in order to register the node and connect it with the customer site At the point of scan the customer record and the equipment...

Страница 10: ...it Model CE04 Radio Type Multi Point to Multi Point Radio Occupied Bandwidth 1760 MHz with 2160 MHz as channel separation according to IEEE 802 11ad Size 240x240x300 mm Weight 4 5kg Pole Size 50 mm 2...

Страница 11: ...Width Deg Approx 5 degrees Antenna Gain 23 dBi Effective Output Power EIRP 40 dBm average 41 dBm peak Max values measured at 3 meters Power Consumption 40 W max Operating Frequency 58 32 62 64 GHz TD...

Страница 12: ...m Usage Outdoor Operating Temperature 40 C to 55 C 40 F to 131 F Relative Humidity Range 4 100 Environment TYPE 3S ENCLOSURE IP65 When properly installed inserted and secured on the pole The pole is p...

Страница 13: ...a problem with the data signal from the Modem or Router Access Denied No data Check with your network provider if there are any network disturbances Restart the node Caution The Pandora360 may be powe...

Страница 14: ...interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on...

Страница 15: ...Page 15 of 15 PoE Power over Ethernet way of powering equipment thrpough an Ethernet cable SFP Small Form factor Pluggable transciever type of connector...

Отзывы: