This secction covers a number of faults, their possible causes, and what can be done to remedy 
the fault. 

Fault 

Poss. 

Cause 

Remedy 

Comment 

Loss of 
signal 

No 
Power 

Make sure that power is ON. 

Make sure that power supply fuses 
are good. 

Make sure the line-of-sight for the 
radio is un-obstructed.

Powered by PoE, check that the 
Modem/Router has power. 

Powered by 48 VDC, check that the 
PSU works. 

Loss of 
data 

No 
signal 

Make sure that the connections are 
correctly inserted. 

Check with network provider if 
there is any problem with the 
network. 

Double-check all equipment 
connections. 

Check if there is a problem with the 
data signal from the Modem or 
Router

Access 
Denied 

No data 

Check with your network provider 
if there are any network 
disturbances. 

Restart the node. 

Caution: 

The Pandora360 may be powered by more than one power source to ensure 

uninterrupted service. To de-energize a Pandora360, disconnect all power sources. 

7. Standards 

We

 

Vivint, Inc. 4931 N. 300 W. Provo, UT 84604 USA 

declare under our sole responsibility that the product Pandora360 (M/N: CE04) complies 
to the following standards:

 

 

Radio Spectrum: FCC Part 15 – §15.255 & §15.247 and IEEE 802.11b/g/n/ad 

 

EMC: FCC Part 15 - §15.207 & §15.209, IEC/EN 61000-4-2, 61000-4-3, 61000-4-4, 
61000-4-5 and 61000-4-6. 

 

Safety: UL/IEC/EN 62368-1, UL/IEC/EN 60950-22, UL 50E and IEC/EN 60529 

 

Safety Human Exposure: Part 15 - 15.247(i), § 15.255(g), Part 1 - § 1.1310 and FCC 
OET BULLETIN 65 

Содержание Pandora360

Страница 1: ...1 1 Introduction 2 Radio Frequency Exposure 3 Directions for Use o 3 1 Preconditions o 3 2 Intended Use 4 Installation Procedure o 4 1 Tools for Installation o 4 2 Unpacking o 4 3 Installing 4 3 1 Pol...

Страница 2: ...are also available from the UPS in the same cable as the DC cable Operations and Maintenance is done via the LAN port or the or SFP port 802 11b g n is used for maintenance operations when a field te...

Страница 3: ...Page 3 of 15 Figure 2 Horizontal Radio Sectors on the Pandora360 Node...

Страница 4: ...lly and vertically are done electronically via software running on the Qualcomm baseband and RF chipset Figure 3 Vertical adjustment of the Pandora360 Radio Lobe The Pandora360 comes in two variants o...

Страница 5: ...ious in the environment and its WiFi management connection makes local management and maintenance from ground safe and easy for the maintenance personnel The device can be installed in meshes with at...

Страница 6: ...h will become the sole responsibility of the installer 3 2 Intended Use The Pandora360 is intended for outdoor use in broadband mesh configurations It is managed and maintained remotely using the Node...

Страница 7: ...ot be able to complete the installation process This roof top location should be a place close to the top of the roof that allows for line of sight to neighboring nodes as provided by the planning dat...

Страница 8: ...der 1 Start with the grounding GND cables make sure the grounding cable is properly terminated Fork lug for 4mm screw and well secured to the Earthing screw on the Strain Relief 2 Fit the Data cables...

Страница 9: ...ems On site an installer will scan the node label on the Pandora360 node in order to register the node and connect it with the customer site At the point of scan the customer record and the equipment...

Страница 10: ...it Model CE04 Radio Type Multi Point to Multi Point Radio Occupied Bandwidth 1760 MHz with 2160 MHz as channel separation according to IEEE 802 11ad Size 240x240x300 mm Weight 4 5kg Pole Size 50 mm 2...

Страница 11: ...Width Deg Approx 5 degrees Antenna Gain 23 dBi Effective Output Power EIRP 40 dBm average 41 dBm peak Max values measured at 3 meters Power Consumption 40 W max Operating Frequency 58 32 62 64 GHz TD...

Страница 12: ...m Usage Outdoor Operating Temperature 40 C to 55 C 40 F to 131 F Relative Humidity Range 4 100 Environment TYPE 3S ENCLOSURE IP65 When properly installed inserted and secured on the pole The pole is p...

Страница 13: ...a problem with the data signal from the Modem or Router Access Denied No data Check with your network provider if there are any network disturbances Restart the node Caution The Pandora360 may be powe...

Страница 14: ...interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on...

Страница 15: ...Page 15 of 15 PoE Power over Ethernet way of powering equipment thrpough an Ethernet cable SFP Small Form factor Pluggable transciever type of connector...

Отзывы: