FCC Part 68 Notice (continued)

Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to 
do this even if other equipment (telephone(s), answering system, computer modem, etc.) already has the telephone line in use. 
To do so, alarm dialing equipment must be connected to a properly installed RJ31X that is electrically in series with and ahead 
of all other equipment attached to the same telephone line. Proper installation is depicted in the fi gure on the previous page. If 
you have any questions concerning these instructions, you should consult your telephone company or a qualifi ed installer about 
installing the RJ31X jack and alarm dialing equipment for you.

Alarm Installation Notes to Installer

For products equipped with an RJ31X jack the line seize feature shall be verifi ed. Be certain the local telephone and incoming line 
connections are not reversed. These lines are not reversed if the alarm dialer can communicate with the central station.

New Services Notes to User

The installation and/or monitoring company shall be notifi ed if new telephone service, e.g. DSL, is installed.

 Industry Canada Notice (for Canadian users)

The Industry Canada (IC) label identifi es certifi ed equipment. This certifi cation means that the equipment meets certain 
telecommunications network protective, operational and safety requirements. The IC does not guarantee the equipment will 
operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local 
telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, 
the company’s inside wiring associated with a single line individual service may be extended by means of a certifi ed connector 
assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent 
degradation of service in some situations.

Repairs to certifi ed equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any 
repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company 
cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and 
internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural 
areas.

CAUTION:

 Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection 

authority, or electrician, as appropriate.

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone 
loop which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices 
subject only to the requirement that the total of the Load Number of all the devices does not exceed 100.

The Ringer Equivalence Number (REN) is used to determine the quantity of devices that may be connected to the telephone line. 
Too many devices may result in some devices not ringing in response to an incoming call. In most, but not all areas, the sum 
of the REN’s should not exceed fi ve (5.0). To be certain of the number of devices that may be connected to the line, contact the 
telecommunications company to determine the maximum REN for the calling area.

Refer to the equipment label for the unit’s load number or REN number

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause 
undesired operation of the device.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et 
d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage 
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope 
rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation 
est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil 
doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

 Regulatory Information

Содержание Go!Control

Страница 1: ...WIRELESS SECURITY SYSTEM USER GUIDE WARNING Owner s Instruction Notice Not to be removed by anyone except occupant Go Control...

Страница 2: ...b access if enabled by your installer The Control Panel displays helpful information regarding the system and sensor status system and alarm history and trouble alerts Being fully supervised the Go Co...

Страница 3: ...e Alerts 22 Trouble Alert Icon 22 Nighttime Trouble Alert Holdoff 22 System Status Icons 23 AC Power Icon 23 Phone Line Failure Icon 23 Backup Battery Status Icon 23 Test Mode Icon 23 Remote Installer...

Страница 4: ...an assign and maintain the other seven User Codes One of the eight User Codes functions as a Duress User Code Controlling the system with this code gives the appearance of normal operation but using i...

Страница 5: ...xit Delay that allows time to leave the premises without triggering the alarm Upon re entry the system offers an Entry Delay through certain points of protection that allows you time to disarm the sys...

Страница 6: ...s RED after an alarm while system is still armed Indicator flashes during power outages system on battery backup Flashes GREEN when ALL sensors are closed ready to arm Flashes ORANGE when ANY sensor i...

Страница 7: ...ide the door jambs Depending on your installation there may be other types of sensors shown below Be sure your installer shows you all the sensors installed in your system Motion Sensor Smoke Detector...

Страница 8: ...Screen Security Screen The Security Screen shows the system status and offers three buttons for ARM MENU and STATUS It also displays the time and date If messages alarm or trouble alerts are pending t...

Страница 9: ...em and can be turned on or off Turning on the burglary protection part of the security system is called Arming the System The burglary protection part of the system can be armed in two modes Stay Mode...

Страница 10: ...The SECURITY button on the display s Home Screen will light green when all perimeter sensors are closed The SECURITY button will be lit orange if ANY perimeter sensor is open Open interior sensors do...

Страница 11: ...manually bypassed so the rest of the system can be armed Depending on programming manual bypasses can remain in place until they are manually removed NOTE Bypassed sensors offer no protection and cann...

Страница 12: ...nel s Arming Screen Normally this option check box is checked so the programmed delay doors allow time for disarming the system after the door is opened Un checking this option box removes the delayed...

Страница 13: ...splayed or press BYPASS ALL to force bypass the displayed sensors NOTE BYPASSED SENSORS WILL NOT BE ABLE TO TRIGGER AN ALARM To bypass sensors you will need to enter a User Code unless the installer h...

Страница 14: ...sabled the system will have to be remotely disarmed with a wireless key fob before entering Exit Delay Restart The Exit Delay Restart option will extend the Exit Delay one time if you need to re enter...

Страница 15: ...reen press ARM If there are any open perimeter door or window sensors the Bypass Screen will appear Close all the sensors displayed or press BYPASS ALL to force bypass the displayed sensors NOTE BYPAS...

Страница 16: ...ISES TO DISARM THE SYSTEM IF YOU HEAR FAST REPEATED BEEPS INSTEAD OF THE NORMAL ENTRY DELAY BEEPS USE EXTREME CAUTION AN INTRUDER MAY STILL BE PRESENT INSIDE THE BUILDING WAIT OUTSIDE AND USE A CELL P...

Страница 17: ...splay will show the order that alarms occurred The alarm memory will automatically clear the next time the system is armed You can also check the CLEAR ALARM HISTORY button and press OK to manually cl...

Страница 18: ...eterdoorsorwindows thesystemwillnotallowarmingtoStay Mode with a wireless key fob All open sensors must be bypassed at the Control Panel first Key Fob Arming to Away Mode To arm the system to Away Mod...

Страница 19: ...by the installer just press the STAY button NOTE Ifthereareopenperimeterdoorsorwindows thesystemwillnotallowarmingtoStay Mode with a wireless keypad All open sensors must be bypassed at the Control P...

Страница 20: ...mergency alarm before you sense a problem and the fire alarm is sounding follow these steps 1 If flames and or smoke are present yell FIRE to alert anyone else around 2 Evacuate all occupants from the...

Страница 21: ...mmends the following placement for smoke detectors Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household The equipment s...

Страница 22: ...dows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these route free from obstructions and post copies of the escape routes in every room 4 Assure that...

Страница 23: ...n an emergency function is activated the siren will sound for its preset time or until a User Code is entered to silence the alarm Panic The PANIC police emergency button sends an immediate panic repo...

Страница 24: ...the upper right corner that is the number of current trouble alerts The trouble alert icon will flash until the trouble alerts are acknowledged then it will light constant until all the troubles are c...

Страница 25: ...testing Remote Installer Access Icon When the system is being remotely accessed by your installer with a computer over the telephone the remote access icon will be displayed Radio Modem Icon If the s...

Страница 26: ...a yellow message icon with an attention symbol in the upper right corner Emergency messages display a red message icon with the bell symbol in the upper right corner Reading Messages When a message ic...

Страница 27: ...n screen 2 Check or un check the types of messages to display Press ALL to check all types Press BACK to return to the message list The filters will reset selecting all types when your message reviewi...

Страница 28: ...elephone remote control system feature is optional It must be enabled by your installer before it can be used Calling the System Your installer selects whether your system supports the remote telephon...

Страница 29: ...hanging up If you already know the remote command telephone key number you can enter it before the command announcement finishes 3 Use the telephone keys to command the system Press for system status...

Страница 30: ...ss USER MANAGEMENT 6 The Users Management Screen displays three users at a time Use the and arrows to scroll through the list Adding a User Code NOTE User Codes 0000 and 0001 are not permitted 1 Press...

Страница 31: ...he User Code s option the EDIT SCHEDULES button will be displayed 2 Press EDIT SCHEDULES to select or edit an existing User Code Access Schedule or create a new one 3 The User Access Schedules Screen...

Страница 32: ...ANCEL to return to the Schedule Type Screen Single Date User Access Schedule 1 Select DATE for the schedule type 2 Press the calendar button to view the Date User Access Schedule Screen 3 Press the da...

Страница 33: ...turn to the Schedule Type Screen Deleting User Access Schedules 1 On the User Management Screen select a User Code that displays the calendar schedule icon 2 Press the EDIT SCHEDULES button 3 On the U...

Страница 34: ...was changed press OK Deleting a User Code 1 On the User Management Screen press the USER button to delete 2 Press DELETE 3 A confirmation screen will display to verify you really want to delete the U...

Страница 35: ...press OK 6 The User 8 edit screen will display Press BACK to return to the User Management Screen Secret Duress Button On the Home Screen in the lower right corner the system logo is displayed The sys...

Страница 36: ...of the filters selected These events include Walk test started or terminated Programming mode started or terminated To view the system history log use the following steps 1 On the Home Screen press S...

Страница 37: ...s signal NOTE Start and stop test reports will be sent to the monitoring station 6 A list of all sensors will be displayed Use the and arrows to scroll through the list 7 Go to each sensor listed and...

Страница 38: ...Screen press SECURITY 2 On the Security Screen press MENU 3 On the Menu Screen press TOOLBOX 4 Enter the Master User Code to access the toolbox 5 Use the and arrows to select Toolbox Screen 3 of 3 6...

Страница 39: ...ERATION To test the cellular radio use the following steps 1 On the Home Screen press SECURITY 2 On the Security Screen press MENU 3 On the Menu Screen press TOOLBOX 4 Enter the Master User Code to ac...

Страница 40: ...ECURITY 2 On the Security Screen press MENU 3 Note the two check boxes on the Menu Screen The CHIME check box button turns the chimes on or off for all the system s sensors The VOICE check box button...

Страница 41: ...n be adjusted from 1 to 12 using the buttons on each end of the bar 8 When finished press OK BacklightTimeout The backlight timeout sets the length of time that the display stays lit after use It can...

Страница 42: ...xpires the system will return to the Toolbox Screen Touch Screen Calibration If the touch screen display buttons are not responding properly use the display calibration option to reset the display To...

Страница 43: ...4 Enter the a valid User Code to access the toolbox 5 On Toolbox Screen 1 of 3 press the arrow 6 On the Toolbox Screen 2 of 3 press SET DATE or SET TIME 7 Use the and arrows to set the current date o...

Страница 44: ...e through the designated exit entry door without setting off the alarm During the Exit Delay beeps sound and faster beeps sound during the last 10 seconds NOTE Arming remotely does not start an Exit D...

Страница 45: ...Exit Delay while the system is armed This allows you to leave the premises without having to disarm and rearm the system When the Quick Exit option is on a QUICK EXIT button will display on the secur...

Страница 46: ...xtend the Exit Delay one time if you need to re enter the premises When the system is armed in the Away Mode or Stay Mode the Exit Delay gives you time to leave without setting off the alarm With the...

Страница 47: ...delay the siren from sounding Disarming during the abort window can display a cancel message depending on the Cancel Display setting see above DIALER DELAY 30 Seconds regular setting _________ Second...

Страница 48: ...lass B computing device in accordance with Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarante...

Страница 49: ...omer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment opera...

Страница 50: ...e equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected to...

Страница 51: ...IPMENT MUST BE CHECKED BY A QUALIFIEDTECHNICIAN AT LEAST EVERYTHREEYEARS Important Power Supply Notice The Control Panel is powered by a plug in power supply In case the power supply becomes unplugged...

Страница 52: ...kind of fire every time In general detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammabl...

Страница 53: ...part of the company for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or pro t or cos...

Страница 54: ...n 29 31 Date range user access schedule 31 DELETE button 31 DELETE SCHEDULE button 31 DELETE USER button 32 Deleting a User Code 32 Dialer delay 45 DISARM button 14 Disarming from Away Mode 14 Disarmi...

Страница 55: ...3 SECURITY button 14 Security screen 6 Sensor bypassing 9 Sensor test 35 Service information 49 Set date and time 41 SET DATE button 41 SET TIME button 41 Setting the duress user code 33 Silencing a f...

Страница 56: ...YOUR LOCAL ALARM INSTALLATION AND SERVICE PROFESSIONAL...

Отзывы: