Vivint Element CT200 Скачать руководство пользователя страница 19

Setup

Vivint Element CT200 Installation Guide

Selecting Cooling Type

1 . From the Thermostat’s Home 

screen, press and hold the 

SIDE button for 3 seconds . The 

Settings menu opens .

2 . Highlight Installer, then press 

the SIDE button . The Install 

Settings menu opens .

3 . Highlight Equipment, then 

press the SIDE button . The 

Equipment menu opens .

4 . Highlight Cooling, the press 

the SIDE button . The Cooling 

menu opens . 

5 . Under Type, press the SIDE 

button until your Cooling type 

is displayed: Air Conditioning, 

Heat Pump, or Evaporate .

6 . Under Stages, press the SIDE 

button until the number of 

stages your system uses is 

displayed: 1(single) or 2 (dual) . 

Selecting Humidity Settings

1 . From the Thermostat’s Home 

screen, press and hold the 

SIDE button for 3 seconds . The 

Settings menu opens .

2 . Highlight Installer, then press 

the SIDE button . The Install 

Settings menu opens .

3 . Highlight Equipment, then press 

the SIDE button . The Equipment 

menu opens .

4 . Highlight Humidity, the press 

the SIDE button . The Humidity 

menu opens .

5 . Under Type, press the SIDE 

button until the type of humidity 

system you have is displayed: 

None, Humidifier, Dehumidifier, 

or Air Conditioner .

6 . Under Activation, press the 

SIDE button until the method 

your humidity system uses is 

displayed: W(ith) Heating, W(ith) 

Cooling, or Independent .

7 . Under Fan, press the SIDE 

button until the fan option 

your humidity system uses is 

displayed: Active or Inactive .

COOLING

TYPE

Air Con.

1

STAGES

Cooling

HUMIDITY

TYPE

ACTIVATION

None

W/ Heating

Active

FAN

Here are the Humidity values:

Humidity Type

o   None

o   Humidifier

o   Dehumid.

o  Air Con.

Activation

o   W/ Heating

o   W/ Cooling

o  Independent

Fan

o   Active

o   Inactive

Humidity

19

Содержание Element CT200

Страница 1: ...RTCOA logo sheet 7aug07 VIVINT ELEMENT THERMOSTAT USER GUIDE COMMUNICATING TOUCH SCREEN THERMOSTAT...

Страница 2: ...ring 8 Mounting Plate 9 Prepare Wires 10 Connecting Wires 11 Power Supply 12 Setup 14 Connecting to a Z Wave network 15 Z Wave and Thermostat Programs 16 Select HVAC Heat Types 18 Test Installation 20...

Страница 3: ...Radio Thermostat Getting Started 3...

Страница 4: ...conditioner Do not reconnect electricity until work is complete Do not short jumper across electric terminals at the control on the furnace or air conditioner to test the system This can damage the th...

Страница 5: ...Getting Started Vivint Element CT200 Installation Guide Interior View Unit Back and Mounting Plate Unit Front Wire terminals Screen Up Button Down Button Bottom Edge Light Side Button 5...

Страница 6: ...mp radio television radiator register fireplace near hot water pipes in the wall or near a stove on the other side of a wall Do not locate in unusual cooling conditions such as on a wall separating an...

Страница 7: ...Radio Thermostat Wiring 7...

Страница 8: ...for identification Refer to the lettered terminal where the wires attach do not use the color of the wires 4 Disconnect wires from the existing thermostat and wind them around a pencil to keep them f...

Страница 9: ...r hole in the mounting plate 2 Position thermostat for best appearance to cover the hole in the wall 3 Mark first and drill a in 6mm hole at each screw location 4 If you are mounting the Thermostat to...

Страница 10: ...these guidelines for safe and secure wire connections Use at least 2 6 in of wire for each of your connections to the Thermostat If you do not have enough wire splice additional wire to allow enough...

Страница 11: ...sily The Thermostat can be externally powered with a power source rated from 12V to 24V AC or DC at 100ma or greater If used connect to the C and RH terminals no polarity The 24VAC C wire is the other...

Страница 12: ...rked polarity in the battery compartments Insert the battery negative end first against the spring then push the positive end in 2 With all the wires connected and the unit attached to the wall it is...

Страница 13: ...cator does not flash Replacing the batteries also helps to prevent leakage that can corrode and damage the thermostat If you are leaving your home for a month or more you should replace the batteries...

Страница 14: ...Vivint Element CT200 User Guide Setup 14...

Страница 15: ...When your primary controller is ready to connect to the Thermostat press the SIDE button to connect This initiates the network connection process The Thermostat s screen says Connecting If the connec...

Страница 16: ...dule and accept commands and then go back to sleep When your thermostat is running on C Wire power the Z Wave radio will stay on and actively help route messages within the Z Wave network The thermost...

Страница 17: ...ptions To go back to a previous screen highlight the arrow at the top of the screen and press the SIDE button After configuring these settings on the Home screen press the side button to turn the syst...

Страница 18: ...der Stages press the SIDE button until your system s heating stage type is displayed 1 single 2 dual 1 Auxiliary or 2 Auxiliary For Heat Pump systems this field is labeled Aux Stages Note Auxiliary st...

Страница 19: ...1 From the Thermostat s Home screen press and hold the SIDE button for 3 seconds The Settings menu opens 2 Highlight Installer then press the SIDE button The Install Settings menu opens 3 Highlight Eq...

Страница 20: ...ss the SIDE button The Heat Test menu opens 5 Highlight START then press the SIDE button The Ther mostat screen displays the following HEAT TIME how long the test has been running in minutes and secon...

Страница 21: ...the test has been running in minutes and seconds ACTIVE the wires the system is using to com municate with the cooling system example Y G CHANGE the amount of temperature change caused during the tes...

Страница 22: ...Vivint Element CT200 User Guide Wiring Diagrams 22...

Страница 23: ...RH RC G WIRES WIRES WIRES Multi stage Heat Pump w Multi stage Aux Heat C Wn Yn R G WIRES Multi stage Cool Multi stage Heat 3 Wire Heat 4 Wire Heat 5 Wire Heat Cool 6 Wire Heat Cool C B or O Y R G C B...

Страница 24: ...e G wire to the G terminal This connects the fan 4 If available connect the C wire to the C terminal 5 Go to Connect Your Wires on page 9 5 Wire Heat Cool 1 Connect the W wire to the W terminal This c...

Страница 25: ...Your Wires on page 9 Multi stage Heat Multi Stage Cool The CT200 can handle up to 2 stages of HEAT and 2 stages of COOL 1 Connect the W and W2 wires to the W and W2 terminals This connects the stages...

Страница 26: ...00 can handle up to 2 stages of Pump compression and 2 stages of AUX heat 1 Connect O wire to the O terminal or the B wire to the B terminal This connects the change over valve If you have both O and...

Страница 27: ...to the correct terminal on the CT200 When controlling a hydronic heating system configure the thermostat as HVAC Type Normal with Heat Type Gas USE ONLY IN HEAT MODE The CT200 must be powered by 24v a...

Страница 28: ...ession for heat pump Y2 Y2 2nd stage COOL control or 2nd stage compression for a heat pump G or F G FAN control C or X C 24VAC power to power thermostat NOTE TRANE uses B for this connection H H Exter...

Страница 29: ...r G G Fan control R or O O X or X2 or C C Trane Products American Standard B C 24VAC power to power thermostat X2 Emergency heat Do not connect tape off Zoned Hot Water 2 wire R RH W W Motor Driven Va...

Страница 30: ...een 34 Menu Screen Settings Screen Compressor Protection 35 Settings 36 Units 37 Humidity Display 38 Info Installer 39 Equipment Comfort Calibration 40 Cycling Staging 41 Network 41 Link Reset 42 Test...

Страница 31: ...Radio Thermostat Product Overview 31...

Страница 32: ...tton to make a selection or scroll through options To go back to a previous screen highlight the arrow at the top of the screen and press the SIDE button To return to the Home screen Use the arrow mul...

Страница 33: ...does not glow When the system is actively heating or cooling the colored glow flickers TIP If your system is in a heating and cooling mode press the SIDE button once to see the other target temperatu...

Страница 34: ...ome screen press the SIDE button once If your system is in a heating and cooling mode press the SIDE button twice Settings Screen This screen enables you to adjust the Thermostat s settings such as di...

Страница 35: ...m You can temporarily override target temperatures and change system modes from the thermostat but you must use the Z Wave application to make permanent changes to programs Compressor Protection The T...

Страница 36: ...Vivint Element CT200 User Guide Customization 36...

Страница 37: ...hold the SIDE button for three 3 seconds 2 Press DOWN to highlight Units then press the SIDE button The currently selected option has a check mark next to it 3 Using the UP or DOWN buttons select an...

Страница 38: ...mark next to it 3 Press UP or DOWN to select a behavior then press the SIDE button to confirm Info Information about the Thermostat device includes POWER The power supply the unit is currently using...

Страница 39: ...ons in this menu enable you to set the heating cooling humidity control and fan equipment behavior See the Installation Guide s Setup section for information on setting those options COMFORT Comfort s...

Страница 40: ...Press DOWN to highlight Comfort then press the SIDE button 4 Press DOWN to highlight Calibration then press the SIDE button The current temperature offset displays 5 Press UP or DOWN to change the va...

Страница 41: ...NETWORK Network settings enable you to link connect the Thermostat to a Z Wave Network and to reset the network connection LINK Before starting this procedure go to your Vivint panel and prepare it fo...

Страница 42: ...IDE button for three 3 seconds 2 Press DOWN to highlight Installer then press the SIDE button 3 Press DOWN to highlight Network then press the SIDE button 4 Press DOWN to highlight Reset then press th...

Страница 43: ...set then press the SIDE button The device restarts RESET 1 From the Home screen press and hold the SIDE button for three 3 seconds 2 Press DOWN to highlight Installer then press the SIDE button 3 Pres...

Страница 44: ...d the thermostat will automatically reconnect to the Z Wave Network Network Disconnected The Thermostat displays this screen when it has lost its connection to the Z Wave Network This screen will only...

Страница 45: ...n which can be determined by turning the equipment off and on try to correct the interference by following these suggestions Reorient or relocate the receiving antenna Increase the separation between...

Страница 46: ...h with line voltage heating systems This device complies with Industry Canada s licence exempt RSSs Operation is subject to the following two conditions 1 This device may not cause interference and 2...

Отзывы: