background image

CLV-411 CAMERA LINK VIDEO SPLI TTER 

User’s Manual 

Document # 200587, Rev 1.0, 5/1/2009

 

 Vivid Engineering 

418 Boston Turnpike #104 • Shrewsbury, MA 01545 

Phone 508.842.0165 • Fax 508.842.8930 

www.vividengineering.com • [email protected] 

 

Содержание CLV-411

Страница 1: ...LINK VIDEO SPLITTER User s Manual Document 200587 Rev 1 0 5 1 2009 Vivid Engineering 418 Boston Turnpike 104 Shrewsbury MA 01545 Phone 508 842 0165 Fax 508 842 8930 www vividengineering com info vivid...

Страница 2: ...2 Medium Application 8 1 5 Specifications 9 2 Interface 10 2 1 Front Panel Connections 10 2 2 Rear Panel Connections 11 2 2 1 Master Select Connector 12 2 3 Camera Connector Signals 13 2 3 1 Cable Sh...

Страница 3: ...rporates high speed 85 MHz interfaces and supports the Camera Link base configuration Medium configuration applications are supported using two CLV 411s Multiple CLV 411s may be cascaded for large par...

Страница 4: ...2 Camera Link Video Splitter CLV 411 Vivid Engineering FRAME GRABBER 3 FRAME GRABBER 1 FRAME GRABBER 2 FRAME GRABBER 4...

Страница 5: ...figuration Medium configuration support using two CLV 411s May be cascaded for large parallel processing systems High speed 85 MHz interface chipset Dynamic master frame grabber selection via opto iso...

Страница 6: ...e ability to share control of the camera between the frame grabbers i e share the master role CLV 411 allows any of the four frame grabbers to act as the master Selection of the master frame grabber i...

Страница 7: ...Serial Comm LVDS Xmtr Channel Link Transmitter LVDS Rcvr LVDS Rcvr Video Data Camera Control Serial Comm LVDS Xmtr Channel Link Transmitter LVDS Rcvr Video Data Camera Control Serial Comm LVDS Xmtr LV...

Страница 8: ...ame grabber Master reassignment occurs instantaneously enabling real time master selection When no connection is made to the DB9 Frame Grabber 1 is master default See Section 2 2 1 for connector pin a...

Страница 9: ...t is not being used in this example frame grabber 1 is the default master The master frame grabber provides camera control and communication as well as performing processing functions The slave frame...

Страница 10: ...rd Camera Link cables Additional Camera Link cables are then used to connect the CLV 411s to the Camera Link frame grabbers Camera Link Video Splitter CLV 411 Vivid Engineering FRAME GRABBER 3 FRAME G...

Страница 11: ...88A Select Connector Female 9 pin D Sub DB9 opto isolated inputs Power Supply Universal wall style w US Europe outlet plugs Power Jack 2 1 x 5 5 mm center positive Power Requirements 5 7 VDC 380 mA ty...

Страница 12: ...s identify which frame grabber is master as discussed in prior sections The video connectors are 3M MDR 26 types as specified in the Camera Link Spec Figure 2 2 identifies the MDR 26 pin positions Cam...

Страница 13: ...ct connector and a DC power jack The MDR 26 connector is a 3M device as specified in the Camera Link Spec The master select connector is a standard 9 pin female D Sub type DB9 Figure 2 4 identifies th...

Страница 14: ...r Select 0 n c 2 no connection n c 3 no connection SEL1 4 Master Select 1 n c 5 no connection SEL0 6 Master Select 0 Return n c 7 no connection n c 8 no connection SEL1 9 Master Select 1 Return Two co...

Страница 15: ...erface in the Camera Link Specification This arrangement provides compatibility with standard Camera Link cables Table 2 2 identifies the signal assignments for the MDR 26 video connectors 2 3 1 Cable...

Страница 16: ...FG X0 12 15 CAM FG X1 24 3 CAM FG X1 11 16 CAM FG X2 23 4 CAM FG X2 10 17 CAM FG Xclk 22 5 CAM FG Xclk 9 18 CAM FG X3 21 6 CAM FG X3 8 19 CAM FG SerTC 20 7 FG CAM SerTC 7 20 FG CAM SerTFG 19 8 CAM FG...

Страница 17: ...and rear endplates The enclosure incorporates a mounting flange The flange contains four predrilled holes 0 15 diameter for convenient equipment mounting A mounting drawing is provided in Figure 3 2 5...

Страница 18: ...y 5 7 VDC and incorporates a standard 2 1 x 5 5 mm DC power jack Power plug polarity is center positive The multi nation wall mount power supply included handles a wide power range 90 264 VAC 47 63 Hz...

Страница 19: ...of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Changes or modifications not...

Страница 20: ...18 5 Revision History Table 5 1 CLV 411 User s Manual Revision History Document ID Date Changes 200587 1 0 5 1 09 Initial release of manual...

Отзывы: