A.  Instructions for attaching the Spring Loaded Cable 

Connector (SLCC) onto the Pinner Bar high voltage 

(HV) cable. 

1.  Trim silicone tubing back to expose HV cable:

•  30 kV Connectors: 3-3/4” [95 mm]

•  60 kV Connectors: 5-5/8” [143 mm]

Trim carefully, 

DO NOT

 nick HV cable 

insulation.

2.  Strip all layers of insulation to expose 3/4”  

[19 mm] of copper conductor. (Wire may be 

difficult to strip; strip in two steps of 3/8”  

[10 mm] lengths.)

3.  Then strip 1/4” [6 mm] of insulation jacket to 

expose inner insulation.

4.  Fold the conductor in half.

5.  Slide a knurled plug and insulating barrel over 

the HV cable.

6.  With one hand, pull the silicone tubing, knurled 

plug, and barrel back to create room for gripping 

the HV cable.

7.  With the other hand, grasp the HV Terminal 

and screw the self-tapping end of it onto the 

white inner core using a clockwise motion.

8.  Ensure that the cable is firmly attached to the 

terminal and that the copper conductor is visible 

through the set screw hole.

9.  Slide the insulating barrel back down over the 

HV Terminal and align the set screw holes.  

Reconfirm that the copper conductor is visible 

through the holes before inserting the set screw 

and fully tightening it into the HV Terminal.

10.  Install the spring onto the end of the HV 

Terminal.