background image

 

15 

4.

 

Regulatory Compliance 

 

4.1.

 

FCC Compliance Statement 

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide a 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. Operation of this equipment in a residential area is likely to 
cause harmful interference in which case the user will be required to correct the 
interference at his/her own expense. 

Changes or modifications not expressly approved by the party responsible for compliance 
could void the user’s authority to operate the equipment. 

 

4.2.

 

EU Notice (European Union) 

Warning:  This  is  a  class  A  product.  In  a  domestic  environment  this  product  may  cause 
radio interference in which case the user may be required to take adequate measures. 

This device complies with EC Directive 89/336/EEC for a Class A digital device. It has 
been tested and found to comply with EN55022A and EN55024. 

 

4.3.

 

Certificate of RoHS Compliance 

Vivid Engineering certifies that the CLV-401A Camera Link Video Splitter complies with 
RoHS Directive 2002/95/EC for the control of hazardous substances. 

 

Содержание CLV-401A

Страница 1: ...K VIDEO SPLITTER User s Manual Document 201058 Rev 1 1 4 2 2018 Vivid Engineering 415 Boston Turnpike Suite 305 Shrewsbury MA 01545 Phone 508 842 0165 Fax 508 842 8930 www vividengineering com info vi...

Страница 2: ...plication 7 1 5 3 PoCL Application 8 1 6 Specifications 9 2 Interface 10 2 1 Front Panel Connections 10 2 2 Rear Panel Connections 11 2 3 Video Connectors 11 2 4 Cable Shield Grounding 12 3 Mechanical...

Страница 3: ...el processing monitoring and recording One frame grabber acts as master and provides control and communications to the camera The second frame grabber receives camera video data only The CLV 401A is c...

Страница 4: ...ini SDR HDR connector via adapting cables Connects to Power over Camera Link PoCL cameras via Vivid Engineering CLR 102 Repeater Adapter Minimal video data pass through latency 3 camera pixel clocks M...

Страница 5: ...blems etc To ensure data integrity Vivid Engineering recommends limiting Camera Link cable lengths when using high pixel clock frequency cameras as follows Table 1 1 Cable Length Recommendations Camer...

Страница 6: ...nk Frame Grabber Slave Link Detect Figure 1 1 CLV 401A Block Diagram The interface between the camera and the master frame grabber contains the entire Camera Link signal set defined in the Camera Link...

Страница 7: ...e grabbers A front panel link status indicator illuminates when the camera video signal is detected The front panel also includes a power indicator The CLV 401A is powered by an external wall plug in...

Страница 8: ...master frame grabber provides camera control and communications and performs the primary processing functions The slave frame grabber cannot control or communicate with the camera but may be used for...

Страница 9: ...Camera Link cables Four additional Camera Link cables are then used to connect the CLV 401A s to the master and slave Camera Link frame grabbers Vivid Engineering Camera Link Video Splitter CLV 401A...

Страница 10: ...re used to connect the CLV 401A to the master and slave Camera Link frame grabbers These cables may standard MDR to MDR or adapting MDR to HDR SDR depending on frame grabber connector type The frame g...

Страница 11: ...es Control communication 5ns max Power Supply Universal wall style w outlet plug set Power Plug 2 1 x 5 5 mm center positive Locking style optional Power Requirements 4 5 9 VDC internally isolated 230...

Страница 12: ...t panel contains two 26 pin MDR video connectors one for connecting to the camera and one for connecting to the master frame grabber The front panel also incorporates LED power and link status indicat...

Страница 13: ...nnection and provides retention Plug polarity is center positive The locking power plug part number is Philmore 2150 or Shogyo MP 121AR SLAVE FRAME GRABBER 4 5 9 VDC Figure 2 2 CLV 401A Rear Panel 2 3...

Страница 14: ...providing a Faraday cage to shield internal circuitry The case is isolated from the CLV 401A circuitry and the cable inner shields avoiding possible safety concerns The camera and frame grabber cable...

Страница 15: ...e incorporates a mounting flange The flange contains four predrilled holes 0 15 diameter for convenient equipment mounting A mounting footprint drawing is provided in Figure 3 2 5 28 1 18 5 1 2 i n c...

Страница 16: ...epts either a standard barrel style power plug or a special locking version see Section 2 2 Power plug polarity is center positive The CLV 401A includes a multi nation wall mount power supply that han...

Страница 17: ...at his her own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 4 2 EU Notice European Union War...

Страница 18: ...16 5 Revision History Table 5 1 CLV 401A User s Manual Revision History Document ID Date Changes 201058 0 1 1 4 12 Preliminary release of manual 201058 1 1 4 2 18 Application and compliance updates...

Отзывы: