12
Table 2-1: MDR-26 Connector Assignments
Camera Link
Signal
Name
Camera
Connector
Pin #
(frame grabber
pinout)
Frame Grabber
Connectors
Pin #
(camera pinout)
Signal Direction
Inner shield
1
1
N/A
Inner shield
14
14
N/A
X0- 25 2
CAM
→
FG
X0+ 12 15
CAM
→
FG
X1- 24 3
CAM
→
FG
X1+ 11 16
CAM
→
FG
X2- 23 4
CAM
→
FG
X2+ 10 17
CAM
→
FG
Xclk- 22 5
CAM
→
FG
Xclk+ 9 18
CAM
→
FG
X3- 21 6
CAM
→
FG
X3+ 8 19
CAM
→
FG
SerTC+ 20
7
FG
→
CAM
1
SerTC- 7 20
FG
→
CAM
1
SerTFG- 19
8 CAM
→
FG
2
6
21
CAM
→
FG
2
CC1- 18 9
FG
→
CAM
1
CC1+ 5 22
FG
→
CAM
1
CC2+ 17 10
FG
→
CAM
1
CC2- 4 23
FG
→
CAM
1
CC3- 16 11
FG
→
CAM
1
CC3+ 3 24
FG
→
CAM
1
CC4+ 15 12
FG
→
CAM
1
CC4- 2 25
FG
→
CAM
1
Inner shield
13
13
N/A
Inner shield
26
26
N/A
“FG” = Frame Grabber, “CAM” = Camera
1
Unused input on
slave
interface, 100-ohm signal termination provided
2
Unused output on
slave
interface, no internal connection