background image

     U.S. Registered Trademark. Patents pending

Copyright      2018 All Rights Reserved.

1

Table of Contents

Table of Contents

Thermostat Operation

Thermostat Quick Reference

Programming

Warranty Information

Page

2-3

4-7

8-10

Una version en español 

de este manual se puede 

descargar en la pagina web 

de la compañia.

Equipment damage hazard. 

Do not operate the cooling 

system if the outdoor 

temperature is below 50 ˚F 

(10 ˚C) to prevent possible 

compressor damage.

Caution:

Rev. 1823

11

P.O. Box 3377

Springfield, MO 65808-3377

TP-P-625

Toll Free : 888-776-1427 

Web: www.vivecomfort.com

Hours of Operation: M-F 9AM - 6PM Eastern 

Vive Comfort

Содержание TP-P-625

Страница 1: ...Operation Manual Operation Manual ...

Страница 2: ... 7 8 10 1 Una version en español de este manual se puede descargar en la pagina web de la compañia Equipment damage hazard Do not operate the cooling system if the outdoor temperature is below 50 F 10 C to prevent possible compressor damage Caution Rev 1823 11 P O Box 3377 Springfield MO 65808 3377 TP P 625 Toll Free 888 776 1427 Web www vivecomfort com Hours of Operation M F 9AM 6PM Eastern Vive ...

Страница 3: ...ies immediately Failure to do so may result in your heat ing cooling system becoming inoperable Freezing or over heating can occur Caution Easy Change Battery Door Temperature Setpoint Buttons Press the or buttons to select the desired room temperature Fan Switch System Switch Temperature Setpoint Buttons LCD Display LOW FAN ON AUTO EmH COOL OFF HEAT Set At LEAVE AM Hold Run Time Program Easy chan...

Страница 4: ...ition until the internal voltage threshold is reached When the thermostat internal voltage threshold is reached all relays will be opened and the thermostat will become inoperable until new batteries are installed Important Battery Door Information Use the finger bevel on the lower portion of the thermostat to open the easy access battery door Replace with 2 AA Alkaline Batteries High quality Alka...

Страница 5: ...e display Permanent Hold If you press the HOLD button on the left of your screen you will see HOLD appear to the right of the ambient temperature in the display The thermostat will now permanently stay at this setpoint and can be adjusted using the or keys To Return to Running Schedule Press the RUN button on the left of your screen to exit either temporary or permanent hold If using programming T...

Страница 6: ...ck a step 7 Press HOLD RUN when completed 1 Select HEAT or COOL with the system switch Note You have to program heat and cool each seperately 2 Press PROGRAM 3 Monday Friday is displayed and WAKE is shown You are now programming the wake time period for the weekday setting 4 Time is flashing Use the or key to make your time selection for the weekday WAKE time period 5 Press PROGRAM 6 The setpoint ...

Страница 7: ...he form below and mail it to the address shown Warranty Registration Online Mail 10 Set Program Schedule 5 1 1 or 7 Day Continue Programming The Thermostat 11 If using 7 Day Programming use previous steps for every individual day Thermostat Model Date Installed Complete form and mail to Thermostat Warranty Registration Vive Comfort P O Box 3377 Springfield MO 65808 3377 Name Address City State Zip...

Страница 8: ...Cut Out For Warranty Registration www vivecomfort com ...

Отзывы: