![Vivax WFL-1001 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/vivax/wfl-1001/wfl-1001_service-manual_1038440057.webp)
P.57
2. Door non-locked & its maintenance
Close the door correctly
Whether the door is
closed correctly
Y
N
N
Push the start button
to start the program
N
Reliable connection
The door
is
invalid and should
be replaced
lock
Y
Y
Y
Y
N
Door non-locked
Whether push the
start /pause button to
start theprogram
Change
the control panel
Whether the voltage
between harness 1 and
harness 3 is about 220v
Whether the harness
connection between the
door lock and the main
board is well
6.TROUBLESHOOTING
Содержание WFL-1001