,QVWDOODWLRQ0DQXDO
,QVWDOODWLRQRI2XWGRRU8QLW
,QVWDOODWLRQRI2XWGRRU8QLW
,QVWDOOWKHXQLWZKHUHLWZLOOQRWEHWLOWHGE\PRUHWKDQ
+RZHYHUGRQRWLQVWDOOWKHXQLWZLWKLWWLOWHG
WRZDUGVWKHVLGHFRQWDLQLQJWKHFRPSUHVVRU
:KHQLQVWDOOLQJWKHRXWGRRUXQLWZKHUHLWPD\H[SRVHG
WRVWURQJZLQGIDVWHQLWVHFXUHO\
,QWKHDUHDZLWKKHDY\VQRZIDOOLIWKHLQWDNHDQGRXWOHW
RIRXWGRRUXQLWLVEORFNHGZLWKVQRZLWLVOLNHO\WRFDXVHRI
WKHEUHDNGRZQ3OHDVHFRQVWUXFWDFDQRS\DQGDSHGHVWDO
RUSODFHWKHXQLWRQDKLJKVWDQGORFDOFRQ¿JXUHG
3ODFHWKHRXWGRRUXQLWDWWKHVHOHFWHGSRVLWLRQLQDGYDQFH
2XWGRRUXQLWWREHIDVWHQZLWKEROWVDWWKHIRXUSODFHVLQGLFDWHGE\
WKHDUURZVZLWKRXWIDLO
'UDLQLQJWKH:DWHUQRIRUFRROLQJRQO\
+ROHVDUHSURYLGHGRQWKHEDVHSODWHRIWKHRXWGRRUXQLWWRHQVXUH
WKDWWKHGHIURVWZDWHUSURGXFHGGXULQJKHDWLQJRSHUDWLRQVLVGUDLQHG
RIIHI¿FLHQWO\
,I D FHQWUDOL]HG GUDLQ LV UHTXLUHG ZKHQ LQVWDOOLQJ WKH XQLW RQ D EDO
FRQ\RUZDOO
,I WKH GUDLQ SRUW LV FRYHUHG E\ D PRXQWLQJ EDVH RU ÀRRU VXUIDFH
SODFHDGGLWLRQDOIRRWEDVHVRIDWOHDVWPPLQKHLJKWXQGHUWKHRXW
GRRUXQLWVIHHW
,QFROGDUHDVGRQRWXVHDGUDLQKRVHZLWKWKHRXWGRRUXQLW
2WKHUZLVHGUDLQZDWHUPD\IUHH]HLPSDLULQJKHDWLQJSHUIRUPDQFH
5HIULJHUDQW3LSLQJ&RQQHFWLRQ
5HPRYHWKH9DOYHFRYHUIURPWKHXQLWE\ORRVHQLQJWKHVFUHZ
%XQGOH WKH SLSLQJ DQG GUDLQ KRVH WRJHWKHU E\ ZUDSSLQJ WKHP
ZLWKYLQ\OWDSHIRUHQRXJKWRFRYHUZKHUHWKH\¿WLQWRWKHUHDUSLS
LQJKRXVLQJVHFWLRQ
,QGRRUXQLWLQVWDOODWLRQ
3DVVWKHGUDLQKRVHDQGUHIULJHUDQWSLSHVWKURXJKWKHZDOOKROH
WKHQVHWWKHLQGRRUXQLWRQWKHPRXQWLQJSODWHKRRNVE\XVLQJWKH
PDUNLQJVDWWKHWRSRIWKHLQGRRUXQLWDVDJXLGH
6ZLQJWKHLQGRRUXQLWWRULJKWDQGOHIWWRFRQ¿UPWKDWLWLV¿UPO\
KRRNHGRQWKHLQVWDOODWLRQSODWH
:KLOHSUHVVLQJWKHLQGRRUXQLWRQWRWKHZDOOKRRNLWDWWKHORZHU
SDUWRQWKHLQVWDOODWLRQSODWH
3XOOWKHLQGRRUXQLWWRZDUG\RXWRFRQ¿UPWKDWLWLV¿UPO\
KRRNHGRQWKHLQVWDOODWLRQSODWH
)RUGHWDFKLQJWKHLQGRRUXQLWIURPWKHLQVWDOODWLRQSODWHSXOOWKH
LQGRRUXQLWWRZDUG\RXZKLOHSXVKLQJWKHERWWRPXSDWWKHVSHFL
¿HGSODFHV
5XQWKHGUDLQKRVHDWDGRZQZDUGVORSHGDQJOH
3XWZDWHULQWKHGUDLQSDQDQGPDNHVXUHWKDWWKHZDWHULVEHLQJ
GUDLQHGRXWVLGH
&DXWLRQ
,QVWDOOWKHGUDLQSLSHIRUSURSHUGUDLQDJH,PSURSHUGUDLQDJHFDQ
UHVXOWLQZDWHUGULSSLQJLQVLGHWKHURRP
50 mm
or more
Do not rise the drain hose.
Do not form the drain hose
into the waved shape.
Do not put the
drain hose end
into water.
Do not put the drain
hose end in the
drainage ditch.
Mounting plate
A
Marking
Push
Push
Drain-water hole
Bottom frame
Drain plug
Hose (available commercially,
inner dia. 16mm)
Drain connecter
Air intake
Min. 30 cm
Air outtake
Min.
30 cm
Min.
200 cm
Valve
side
Min.
50 cm
Содержание ACP-18CH50GECI
Страница 1: ...ACP 18CH50GECI ACP 22CH65GECI Service manual ENG RoHS ...
Страница 2: ......
Страница 5: ...ACP 18CH50GECI ACP 18CH50GECI I ...
Страница 6: ...ACP 18CH50GECI O ...
Страница 7: ...ACP 22CH65GECI ACP 22CH65GECI I ...
Страница 8: ...ACP 22CH65GECI O ...
Страница 10: ...6SHFL FDWLRQV ACP 18CH50GECI ACP 18CH50GECI ACP 22CH65GECI ACP 22CH65GECI ...
Страница 12: ...ON OFF 5 7 1 2 4 5 148 193 685 130 W H D ACP 22CH65GECI ACP 18CH50GECI ACP 18CH50GECI ACP 22CH65GECI ...
Страница 13: ...899 818 596 378 303 343 550 Model ACP 18CH50GECI O 700 368 955 560 396 340 890 Model ACP 22CH65GECI O ...
Страница 39: ...ACP 18CH50GECI I ...
Страница 41: ...ACP 22CH65GECI I ...
Страница 43: ... SORGHG 9LHZV DQG 3DUWV LVW 7KH GDWD DERYH DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH ACP 18CH50GECI O ...
Страница 45: ...ACP 22CH65GECI O ...
Страница 96: ......
Страница 97: ......
Страница 98: ......