Removal Procedure
1
1
1
6. Remove 4-way valve assy (not available for cooling only unit)
Discharge the refrigerant completely; unsolder
the pipelines connecting the compressor and
the condenser assy, and then remove the
4-way valve assy.
7. Remove compressor
Remove the 3 foot nuts fixing the compressor
and then remove the compressor.
Remove the 3 screws fixing the isolation sheet
and then remove the isolation sheet.
8. Remove chassis sub-assy and condenser sub-assy
compressor
4-way valve assy
isolation sheet