![Vivax ACP-12CT35GECI Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/vivax/acp-12ct35geci/acp-12ct35geci_service-manual_1038061054.webp)
50
Removal Procedure
Steps
Procedure
7. Remove piping stopper
Loosen clasps between piping stopper
and bottom case, and then pull the
piping stopper outwards to remove it.
8. Remove evaporator
Loosen the clasps between evaporator
and bottom case and then pull the
evaporator outwards to remove it.
9. Remove reversion loop
Remove 4 screws on reversion loop, and
then remove the reversion loop.
screw
piping stopper
evaporator
assy
reversion loop