30
8. Troubleshooting
8.1 Indoor unit error display
For 9k, 11k, 18k
Display
Operation lamp flash times Timer lamp
Failure
E1
1 X
EEPROM error
E2
2 X
Zero crossing signal detection error
E3
3 X
Indoor fan speed has been out of control
E5
5 X
Indoor room temperature sensor T1 open circuit
or short circuit
E6
6 X
Evaporator coil temperature sensor T2 open
circuit or short circuit
EC
2 O
Refrigerant leak detection error
For 24k
Display
Operation lamp flash times Timer lamp
Failure
E1
1 X
EEPROM error
E2
2 X
Zero crossing signal detection error
E3
3 X
Indoor fan speed has been out of control.
E4
4 X
Default
E5
5 X
Indoor room temperature sensor T1 open circuit
or short circuit
E6
6 X
Evaporator coil temperature sensor T2 open
circuit or short circuit
EC
2 O
Refrigerant leak detection error
E9
9 X
Indoor unit and outdoor unit communication error
O
˄
light
˅
X
˄
off
˅
ƿ˄
flash
˅