29
7.4.5 Drying mode
7.4.5.1 The compressor is cycled running by 10 minutes on and then 5 minutes off. The indoor fan will
keep running at low speed.
7.4.5.2 In drying mode, if the room temperature is lower than 10
Ԩ
, the indoor fan will run at breeze
while the compressor and outdoor fan will stop and not resume until room temperature exceeds 13
Ԩ
.
7.4.5.3 The system protection is active in this mode.
7.4.6 Forced operation function
Press the touch button continually, the AC will run as below sequence:
Forced auto
→
Forced cooling
→
Off
Forced cooling mode:
The compressor and outdoor fan keep running and the indoor fan runs at low speed. After running for 30
minutes, AC will turn to auto mode with 24
ć
setting temperature.
Forced auto mode:
The action of forced auto mode is the same as normal auto mode with 24
ć
setting temperature.
z
When AC receives signals, such as switch on, switch off, timer on, timer off, mode setting, fan
speed setting, sleeping mode setting, follow me setting, it will quit the forced operation.
z
The forced operation function cannot be memorized if power off.
7.4.7 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart module.
In case of a sudden power failure, the module memorizes the setting conditions before the power failure.
The unit will resume the previous operation setting (not including Swing function) automatically after 3
minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes and
then turn to drying mode as 24
Ԩ
setting temp.
7.4.8 Refrigerant Leakage Detection
When the compressor is running, the indoor fan motor will run without anti-cold air function.
When the compressor is off, the indoor fan motor is off .