CONTROL SPECIFICATION
20
FAN MODE
In this mode, the outdoor unit does not operate. The indoor fan alone operates.
Press UP & DOWN SWING button or LEFT & RIGHT SWING button to change air flow direction.
Press FAN SPEED button to change the fan speed of indoor unit.
LIGHT-WAVE MODE (only applied to light-wave series)
Every press of LIGHT-WAVE button, the air conditioner will cycle in the
mode. Once entering the light-wave mode, the light-wave icon will light up on display panel of the
indoor unit and the air conditioner will judge whether to connect the light-wave tube by ambient
temperature.
order of enter/quit light-wave
TURBO function (only applied to turbo series)
This function will make the air conditioner heat or cool quickly and during this period, the noise of the
air conditioner will increase. Turbo function can be only started up in heat or cool mode(turbo heating
or turbo cooling) otherwise, it can not be started up. When the air conditioner is in cool or heat mode,
press turbo button to initiate turbo function, the remote controller displays TURBO and the icon of
fan speed is ,meanwhile the air conditioner cannot be controlled by the remote controller. Press
turbo button again or start up sleep mode or transit modes to exit turbo function. After exiting turbo
function the fan runs at low speed.
“
”
“
”
FRESH AIR function (only applied to fresh air series)
When the air conditioner is on, press fresh air button to initiate or stop fresh air function. While this function
is initiated the remote controller displays FRESH AIR ,meanwhile the fan starts to run, the letter
FRESH AIR extinguishes and the fan stops if fresh air function stops.
“
”
“
”
”
”
CLEAN function (only applied to clean series)
When the air conditioner is on, press CLEAN/PLASMA button for 3 seconds to initiate or stop clean function.
While this function is initiated the remote controller displays
CLEAN and it will extinguish if clean function
stops. Please note that after clean function starts up, the evaporator will only clean automatically on the
condition that the air conditioner is turned off normally.Moreover, after the evaporator is checked dirty by the
system, the LED of indoor unit will display CLEAN
to remind you of starting up the clean function.
”
”
AIR QUALITY CHECKING function (only applied to air quality checking series)
When the air conditioner is on, air quality checking function starts up automatically, at the same time the air
quality indicator light on the indoor unit will flash once, which shows that the air conditioner starts up air
quality checking function. After the air quality checking function is initiated, if the air quality is good the
indicator light extinguishes; if the air quality is bad the indicator light will flash 5 times then lighten. Air
quality is showed through the lighteness of the indicator light, the lighter the indicator the worse the air
quality. When the indicator light is lighten, fresh air function is supposed to be started up. After the air is
renewed, the system will stop or continue fresh air function according to the air quality. You can also stop
fresh air function as you like. When the air conditioner is turned off, the indicator light will flash once to
show the air quality checking function is in gear. And every time starting up inoizer, aux-heat, light-wave,
plasma,clean and turbo function the indicator light will flash once.
”
”
Содержание ACP-07CH21ZNLO
Страница 1: ...ACP 07CH21ZNLO ACP 09CH25ZNLO ACP 12CH35ZNLO Service manual ENG RoHS ...
Страница 2: ......
Страница 30: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O Exploded Views and Parts List 31 ...
Страница 31: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O ...
Страница 32: ...ACP 12CH35ZNLO O ...
Страница 37: ......
Страница 38: ......
Страница 39: ......