background image

www.vivax-metrotech.com

The Loc3-25Tx Transmitter Insert

NOTE

The 25-watt transmitter ships with the Li-ion battery tray as a standard part. Alkaline can be used with 

the 25-watt transmitter, but the power output will be limited to 10-watts.

WARNING

Use only Vivax-Metrotech recommended charger.

Do not attempt to replace the rechargeable batteries or remove battery covers.

Return to Vivax-Metrotech or a Vivax-Metrotech approved service center for replacement.

2.1    Charging the Transmitter Battery Tray

The rechargeable battery tray can be charged while attached to the transmitter or on its own. 

1.  Connect the charger to the charging socket on the transmitter's side or directly into the battery tray's charging socket.
2.  The LED on the charger will glow red while charging and turn green when fully charged.

FUSE

            

Internal Charger Socket

Plug the charger into the charging socket on the side of the transmitter or directly into the battery tray.

NOTE

The rechargeable tray cannot be charged from a 12V DC source.

WARNING

Only use a charger supplied by Vivax-Metrotech Corp. Using non-approved chargers may result in 

damage to the equipment or overheating/explosion.

The battery condition (charge) is displayed on the left side of the display.

Follow instructions detailed in the General Safety & Care Information section of this manual. Only use the battery charger 
supplied as using an unapproved charger may damage the battery pack and may cause overheating.

2.2    Removing and Installing the Battery Tray

Removing the battery tray

Installing the battery tray

FUSE

FUSE

1.  Pull out the bottom of the catch
2.  Lift the transmitter from the battery tray

1.  Lower the transmitter into the tray
2.  Push up button underneath the catch while holding it up. 
3.  Push in the bottom of the catch until you hear a positive 

“click."

  

Page 3

Содержание Loc3-25Tx

Страница 1: ...Units mA volts ohms 5 Speaker level 6 Output step bar graph 7 Battery level or DC Input icon 8 Digital readout mA volts ohms Output Protect Warning The transmitter checks the line when connected Output protected against accidental momentary connection to up to 230V AC RMS it will display the high voltage warning icon and not allow the transmitter to operate In addition the transmitter is protected...

Страница 2: ...Output speakON socket 25 Watt transmitter for the direct connection lead Charger socket to charge rechargeable battery pack Transmitter 19V DC power lead is used to power the transmitter from AC DC power supply Fuse 4A 250V this protects the transmitter circuitry in the event of the transmitter receiving up to 250V incoming voltage on the output leads or higher than the allowed current A beeper is...

Страница 3: ...ed FUSE Internal Charger Socket Plug the charger into the charging socket on the side of the transmitter or directly into the battery tray NOTE The rechargeable tray cannot be charged from a 12V DC source WARNING Only use a charger supplied by Vivax Metrotech Corp Using non approved chargers may result in damage to the equipment or overheating explosion The battery condition charge is displayed on...

Страница 4: ...splay FUSE Wherever a direct connection can be safely made without the risk of injury damage to the customer s plant or the transmitter it is the best way of applying the transmitter s signal The positioning of the ground connection can also influence the degree of coupling experienced Ground connections generally should not be made to other pipes or cables or above ground metallic structures such...

Страница 5: ...n is needed FUSE WARNING When applying the clamp to cables that carry electricity be sure to follow your company s safety instructions and procedures Beware that if applied around a high voltage cable that cable may induce a current in the clamp causing it to snap shut or jump quite dramatically always apply clamps carefully 4 Transmitter Frequencies The Loc3 25Tx transmitters are supplied with a ...

Страница 6: ...educe battery life All other settings remain the same as the last setting used 4 2 Most Used Frequencies Frequency Selection Feature This feature allows the operator to choose the most used frequencies from a list of frequencies Once these frequencies are selected in the main menu the user can scroll through them by pressing the f pushbutton The user can add or remove frequencies from the above li...

Страница 7: ... to exit the Frequency Menu and return to the main display 6 A particular frequency in the chosen list of frequencies can be selected from the screen by pressing the f pushbutton until the wanted frequency is displayed at the top of the main screen Vivax Metrotech Corp Headquarters 3251 Olcott Street Santa Clara CA 95054 USA T Free 1 800 446 3392 Tel 1 408 734 1400 Fax 1 408 734 1415 Email SalesUS...

Страница 8: ......