![Vitus Audio MP-I201 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/vitus-audio/mp-i201/mp-i201_owners-manual_1037627021.webp)
21
MP-S201
| Version 1
4. operation & service
Mains fuse
The mains fuse is accessible
from the outside of the
amplifier. You will find the
mains fuse, just below the
power inlet. If the fuse blows,
then you can easily replace
it. The fuse only blows on the
occurrence of power surges
or if there is a fault in the
unit. Normally power surges
cause no other damage other
than blowing the fuse. When
the fuse blows repeatedly on
replacement, then the unit
most likely has a malfunction.
In case of malfunction the
unit must be returned to Vitus
Audio for repair.
Fuse type:
Left and Right Channel:
230V :
20x5mm 6,3A T
115V :
20x5mm 10A T
100V :
20x5mm 12A T
HRC fuse
Digital Control:
230V :
20 x 5mm – 500mA – T
LBC fuse (Time lag fuse)
100-120V :
20 x 5mm – 1 A – T
- LBC fuse (Time lag fuse)
Replacing the fuse with a fuse
of a type and rating different
from the original fuse, might
result in damage to the unit
and injury to you (the user).
Damage to the unit as a result
of wrongly replacing the
mains fuse, will invalidate the
guarantee.
For an explanation of how to
replace the fuse see chapter 4
“replacing a blown fuse”.
4. operation &
service
Содержание MP-I201
Страница 1: ...MP I201 Owner s Manual ...
Страница 14: ...14 MP S201 Version 1 3 operation MP I201 Front panel Class A AB MENU SELECT STANDBY MUTE M P I O ...
Страница 42: ...Picture 2 MP I201 Front 42 MP S201 Version 1 8 pictures MP I201 Front ...
Страница 43: ...43 MP S201 Version 1 8 pictures MP I201 Inside 8 pictures ...