Question/Problem - Cause
Causa
Solution
The motor does not start or turns slowly:
•
No supply voltage;
•
The supply voltage is too low;
•
The temperature is too low;
•
Failure in the pressure switch;
•
Failure in the motor;
•
Check the plug, socket and circuit breaker of the power
supply circuit;
•
Avoid too long extension cords;
Use an extension cord with enough transversal cross-
section;
•
Do not operate the compressor with outside
temperatures below +5°C;
•
Repair or replace;
•
Repair or replace;
The compressor runs, but has not enough pressure or has
a low discharge capacity:
•
The air filter is clogged;
•
There is a leak in the non-return and safety valve;
•
There is a leak in the discharge pipe;
•
The sealing gaskets are damaged;
•
The tank drain screw is leaking;
•
The cylinder and segments are damaged;
•
Clean or replace;
•
Check and repair the valves;
•
Check and repair;
•
Replace the damaged sealing gaskets;
•
Tighten the screw by hand;
Check the screw’s joint and replace, if
necessary;
•
Repair or replace;
The motor stops suddenly:
•
The moving parts are damaged because of the
absence or low oil level in the compression pump;
•
The moving parts are damaged or blocked;
•
Check the condition of moving parts and replace if
necessary;
•
Repair or replace damaged parts;
The air compressor stops and the thermal overload
protection switch trips:
•
Motor overheating;
•
There is blockage or damage to rotating parts, which
causes the motor to overheat;
•
Let the compressor cool down, reset the overload relay
and switch the compressor back on;
•
Remove or replace the parts, press the thermal
overload protection switch and restart the compressor;
The compressor runs, the pressure is shown on the
pressure gauge, but the air tools do not function:
•
There is a leak in the compressed air hose;
•
There is a leak in the quick-release coupling;
•
The pressure set in the pressure regulator is too low;
•
Check the compressed air hose and tools. Replace
them, if necessary;
•
Check quick-release coupling and replace if necessary;
•
Increase the pressure in the air outlet pressure
regulator;
Excessive oil consumption:
•
The oil level is too high;
•
The cylinder and segments are damaged;
•
Check and adjust the oil level;
•
Repair or replace;
Содержание PRO POWER VICOC300B
Страница 1: ...COMPRESSOR COM CORREIAS COMPRESOR CON CORREA BELT COMPRESSOR COMPRESSEUR A COURROIE...
Страница 5: ...COMPRESSOR 300 COM CORREIAS 10BAR VICOC300B...
Страница 19: ...COMPRESOR 300 CON CORREA 10BAR VICOC300B...
Страница 33: ...10BAR BELT COMPRESSOR 300 VICOC300B...
Страница 47: ...COMPRESSEUR 300 COURROIE 10BAR VICOC300B...
Страница 62: ......
Страница 63: ......
Страница 64: ...VICOC300B_REV01_MAI22...