background image

 

 

                                                                                                         

 

To prevent fire or shock hazard, do not expose the unit to rain or moisture. 

 

                 

This symbol is intended to alert the user to the presence of important                 
operating and maintenance (servicing) instructions in the literature   
accompanying the unit. 

               
 

                 

This symbol is intended to alert the user to the presence of   
uninsulated "dangerous voltage" within the product's enclosure that   
may be of sufficient magnitude to constitute a risk of electric shock. 

 
 

 

 
 

   

   

   

   

  Warning (NTSC version) -- This equipment has been tested and found to comply with the limits for a Class 

A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference when the equipment is operated in a commercial environment. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instruction manual, may cause harmful interference to radio communications. Operation 

of this equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at their own expense. 

 

Caution -- Any changes or modifications in construction of this device that are not approved by the party 

responsible for compliance could void the user's authority to operate the equipment. 

 
Notice -- The images used in this manual are processed to help comprehension and 
may differ from the actual video of the camera.   
 
1. Safety Instructions and Notes 

 

• Please read these safety and operating instructions before placing the camera into operation. 
• Keep the manual in a safe place for later reference. 

• Pay attention to safety when laying the connection cable and observe that the cable is not subjected to 

heavy loads, kinks, damage or moisture. 

• Never open the device to expose boards or lenses. 
  The warranty becomes void if repairs are undertaken by unauthorized persons. 
• Only authorized service centers may perform maintenance or repairs. 

WARNING 

Caution 
 
To  prevent  electric  shocks 
and  risk  of  fire  hazards,  do 
NOT  use  other  than  specified 
power source. 

 

 

 

 

 

 

Содержание VTC-3516

Страница 1: ...l darkness up to 150 feet 0 003 Lux F1 2 40IRE 0 Lux with IR LEDs On E WDR by Adaptive Tone Reproduction 3 5 16mm Varifocal Auto Iris Lens with External Adjustments for Focus and Zoom 2DNR Noise Reduc...

Страница 2: ...1 1 Safety Instructions and Notes 2 General Descriptions 3 Supplied Items 4 Part names 5 Installation Instructions 6 Setup Menu 7 Specifications 8 Dimensional Drawings 2 3 4 4 5 7 20 21...

Страница 3: ...ications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Caution Any...

Страница 4: ...rporates 2 D noise reduction signal processing ICR mechanism Enhances sensitivity up to 10x at night Accepts infrared light 24VAC 12VDC dual power design Offers flexibility of installation Ensures rel...

Страница 5: ...nshield with Attachment thumb screw for Sunshield panel 1x 3mm Hex L wrench 4x anchors 4x Wall mounting screws 1x Video Sub output cable 4 Part Names 4 1 Front view 3 Supplied Items Sunshield attachme...

Страница 6: ...g the AC adapter to the AC outlets to avoid an improper reset from power jitter and possible damage from voltage surge 5 1 Mounting the camera 1 Drill 4 holes into the wall or ceiling using the suppli...

Страница 7: ...DC supply otherwise IR LEDs will not operate at night Primary and secondary grounds are completely isolated to avoid possible ground loop problems 5 3 Limit of pan and tilt 1 Pan limit Pan is limited...

Страница 8: ...change the settings and press to select or enter The FACTORY DEFAULT in this manual may NOT be the same as the default values set by the FACTORY due to feature improvements or customer requirements To...

Страница 9: ...OR BRIGHTNESS CONTRAST SHARPNESS HUE or GAIN See 6 6 PICT ADJUST menu for details WHITE BAL ATW Sets ATW PUSH USER1 USER2 ANTI CR MANUAL or PUSH LOCK See 6 7 WHITE BAL menu for details ATR OFF Sets ON...

Страница 10: ...To enter SHUTTER AGC menu press button at MAIN menu 1 SHUTTER AGC MAIN menu 2 Default Descriptions NR Sets the noise reduction parameters for NR MODE and Y LEVEL C LEVEL See 6 10 NR menu for details...

Страница 11: ...for the best sensitivity unless it is in Flickerless mode To set Flickerless mode MAIN SHUTTER AGC MANUAL SHUTTER must be set to 1 100 NTSC 1 120 PAL and MAIN SHUTTER AGC AUTO MODE to AUTO IRIS SHUT A...

Страница 12: ...e is unchanged AGC 6 00 Sets AGC gain in dB Higher gain compensates brighter but noise increases Manual AGC can be set to 6 12 18 24 30 36 42 or 44 8 dB AUTO IRIS Default Descriptions TYPE DC MUST BE...

Страница 13: ...the color equipment but shows the same resolution as color video If set to OFF the color burst signal is removed from B W video and shows better resolution but it is possible that a compatibility prob...

Страница 14: ...e appear harsh and will show more noise It may also show line flicker at the edge of object in the picture HUE 128 Adjusts hue for NTSC version only GAIN 128 Increases or decreases the color gain of t...

Страница 15: ...hite balance that is user programmable by B GAIN R GAIN will be automatically adjusted in accordance with B GAIN and useful only with consistent steady lighting PUSH LOCK is a fixed white balance wher...

Страница 16: ...n MAIN menu 1 ATR MANUAL WB Default Descriptions LEVEL 064 Adjusts the manual white balance by LEVEL B GAIN ATR Default Descriptions LUMINANCE MID Compresses the highlight area and enhances the dark a...

Страница 17: ...uch as sunlight limiting the affect of silhouetting The Highlight Compensation HLC function is used to black out highlighted areas that may blind the camera in order to enable a clear visual image of...

Страница 18: ...ion windows as programmed in sizes and positions AREA SEL 1 4 Selects one of AREA1 AREA4 to be adjusted TOP BOTTOM button moves up and button moves down the top bottom border of the selected window at...

Страница 19: ...tions AREA SEL 1 8 Selects one of AREA1 AREA8 to be adjusted TOP BOTTOM button moves up and button moves down the top bottom border of the selected window at AREA SEL LEFT RIGHT button moves left and...

Страница 20: ...MERA ID input line move a cursor to CLR on COMMAND LINE and press button To set the location of CAM TITLE to be displayed on the monitor move a cursor to POS and press button and then menu disappears...

Страница 21: ...eo Output VBS 1 Vpp 10 75ohm TV System 2 1 Interlace Scan Frequency 59 94Hz V 15 734Khz H 50Hz V 15 625Khz H Synchronization Internal Line Lock Default Internal Noise Reduction 2DNR E WDR YES by ATR A...

Страница 22: ...21 8 Dimensional Drawings 2 95 75mm 1 4 35mm 2 75 70mm 3 5 90mm 3 4 86mm 4 35 110 5mm 3 56 90 5mm 12 48 317mm 10 7 270 5mm...

Страница 23: ...22...

Страница 24: ...Reseller The product must have been used only for its intended purpose and not been subjected to damage by misuse willful or accidental damage caused by excessive voltage or lightning The product must...

Страница 25: ...28492 Constellation Road Valencia ca 91355 WWW VITEKCCTV COM 888 VITEK 70...

Отзывы: