Motion detection record
Free Dynamic DNS
System components and Installation
Requirements for installation and safety
This chapter is for the requirements for safe installation and use.
This kit should be installed on a flat table or in a rack.
The location in which the DVR is installed in the room is very important for
proper operation of the system. When the DVR is installed too closely together
or the location is poorly ventilated, the DVR may not operate properly and
maintenance of the DVR may be difficult. Make sure that the air should be
sufficiently circulated within the system operating room and the cover of the
main system must be tightly fastened to prevent malfunction.
There are high voltage parts inside. Do not open the cover during operation.
The DVR must be installed in a place that meets the following environmental
conditions.
• Operating temperature: 5°C ~ 40°C (41°F ~ 104°F)
• Operating humidity: 30% ~ 90% RH
• Input voltage: DC +12V 5A
• Power usage: About 25Watts
• Frequency: 60Hz/50Hz
Main replacement parts
• Hard disk (When HDD is factory-installed.): 1 year (25°C/77f environment)
• Cooling fan: 1 year (25°C/77f environment)
• Battery: 2 years (25°C/77f environment)
CAUTION
During the operation of this product, the fluctuation of input voltage must be
within 10% of the rated voltage and the external power outlet must be
grounded, otherwise, it may cause electric shock or malfunction of the product.