background image

VT-16P250WS / VT-24P370WS: 16 / 24 Port L2 Web Smart Ethernet PoE Switch

11

 

 

 
 

Administrator -> Firmware Update 

You must enter the password of device in order to determine the firmware needs to be updated. 
After a correct password the switch will erase the old firmware first.   
After completing the erase you will see the screen below. Specify the Firmware Path (or Browse for one) that you 
are going to use, and then click 

Update

. The state will show ‘OK’ after completion and ‘Fail’ if firmware upgrade 

fails or cannot be completed for any reason.   

 

 

 
Administrator -> Reboot Device 

Provide a safe way to reboot the system. Click 

Reboot

 to restart the switch.   

Содержание VT-16P250WS

Страница 1: ...itch Visual PoE Status via LED PoE ON OFF Control PoE Schedule PD Alive auto Check High back plane bandwidth 7 2Gbps 8 8bps Port mirror and bandwidth control IEEE802 3x Flow control Conforms to IEEE802 3 IEEE 802 3u IEEE 802 3ab IEEE802 3z IEEE802 3af IEEE802 3at Supports Port Based VLAN 802 1Q Tag VLAN Supports IEEE802 3ad Port trunk with LACP Supports IEEE 802 1p class of service Supports Broadc...

Страница 2: ...er Cord 5 3 5 Connecting Ethernet Interface 5 4 Troubleshooting 7 5 Getting Started 7 5 1 Management Options 8 5 2 Using Web based Management 8 6 Configuration 8 6 1 Welcome 8 6 2 Administrator 9 6 3 Port Management 12 6 4 VLAN Setting 14 6 5 Per Port Counter 16 Per Port Counter Port Counter 16 6 6 QoS Setting 16 6 7 Security 17 6 8 Spanning Tree 18 6 9 Trunking 20 6 10 DHCP Relay Agent 21 6 11 Ba...

Страница 3: ... the IEEE 802 3af at specification and is completely compatible with existing Ethernet switches and networked devices Because the Power Sourcing Equipment PSE tests whether a networked device is PoE capable power is never transmitted unless a Powered Device is at the other end of the cable It also continues to monitor the channel If the Powered Device does not draw a minimum current because it has...

Страница 4: ...iew of the switch consists of an AC power connector Power Switch and Fuse 3 Hardware Installation 3 1 Package contents Package contents include the following n PoE Switch 16x10 100 PoE ports with 2x10 100 1000 combo ports Ethernet Switch n AC power cord n Two 2 rack mount ears and Six 6 screws n Four 4 adhesive backed rubber feet n User s manual IMPORTANT If any piece is missing or damaged please ...

Страница 5: ...the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading n Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing...

Страница 6: ...g stud or bolt on rack where the switch is installed Step 6 Verify if the connections at the ground connector on the switch and the rack are securely attached 3 4 Plugging in the AC Power Cord Users may now connect the AC power cord into the rear of the switch and to an electrical outlet preferably one that is grounded and surge protected Power Failure As a precaution the switch should be unplugge...

Страница 7: ... receive negative TPRXD2 Input 4 Data Bi directional positive BI_D3 Bidirectional 5 Data Bi directional negative BI_D3 Bidirectional 7 Data Bi directional positive BI_D4 Bidirectional 8 Data Bi directional negative BI_D4 Bidirectional Cable connection and colors follow the regulations in EIA TIA 568A as follows Cable connection and colors follow the regulation in EIA TIA 568B as follows Choose the...

Страница 8: ...nections 100Ω Category 5 cable for 100Mpbs connections or 100Ω Category 5e above cable for 1000Mbps connections Also be sure that length of any twisted pair connection does not exceed 100 meters 328 feet We suggest using Category 5e cable when connection to power a device Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include ...

Страница 9: ...n of your device n A PC with a RJ 45 Ethernet connection n A standard Ethernet cable Connect the Ethernet cable to any of the ports on the front panel of the switch and to the Ethernet port on the PC Login Web based Management In order to login and configure the switch via an Ethernet connection the PC must have an IP address in the same subnet as the switch For example if the switch has an IP add...

Страница 10: ...istrator System IP Configuration There are two ways for the switch to obtain an IPaddress Static and DHCP Dynamic Host Configuration Protocol When using static mode the IP address Subnet Mask and Gateway can be manually configured When using DHCP mode the Switch will first look for a DHCP server to provide it with an IP address including network mask and default gateway before using the default or...

Страница 11: ...out period for security purposes when there is no action for a specific time span in the Web based Management If the current session times out expires the user is required a re login before using the Web based Management again Selective range is from 3 to 30 minute and the default setting is 5 minutes Administrator Load default setting Provide a safe reset option for the switch All configuration s...

Страница 12: ...sword the switch will erase the old firmware first After completing the erase you will see the screen below Specify the Firmware Path or Browse for one that you are going to use and then click Update The state will show OK after completion and Fail if firmware upgrade fails or cannot be completed for any reason Administrator Reboot Device Provide a safe way to reboot the system Click Reboot to res...

Страница 13: ...red and adjusted for optimum configuration Enable Enable or disable the port s connection Auto Nege Enable or disable port auto NDI MDIX Speed Copper connections can operate in Forced Mode settings 1000M Full 100M Full 100M Halt 10M Full 10M Half Auto or Disabled The default setting for all ports is Auto Duplex Copper connections can operate in Full Duplex or Half Duplex Mode ...

Страница 14: ...Port Click all to include all ports into port mirroring RX receive mode Duplicates the data that received from the source port and forwards it to the Target Port Click all to include all ports into port mirroring Both transmit and receive mode Duplicate both the data transmitted from and data sent to the source port and forwards all the data to the assigned Target Port Click all to include all por...

Страница 15: ...t packets Once a packet storm has been detected the Switch will drop packets coming into the Switch until the storm has subsided 6 4 VLAN Setting VLAN Setting VLAN Mode A VLAN is a group of ports that can be anywhere in the network but communicate as though they were in the same area VLANs can be easily organized to reflect department groups such as R D Marketing usage groups such as e mail or mul...

Страница 16: ...n assign multiple ports to the same VLAN or each port to a separate VLAN 802 1Q VLAN By default 802 1Q VLAN is disabled With 802 1Q VLAN enabled the VLAN VID 1 is created by default with an empty VLAN name field and all ports are configured as Untagged members VLAN Setting Add VLAN Click to create a new VLAN name and to select VLAN ports The VLAN name should be less than 10 characters To save the ...

Страница 17: ...t L2 Web Smart Ethernet PoE Switch 16 6 5 Per Port Counter Per Port Counter Port Counter The Statistics screen displays the status of each port packet count 6 6 QoS Setting QoS Setting Priority Mode QoS Setting Port 802 1p IP DS based ...

Страница 18: ...VT 16P250WS VT 24P370WS 16 24 Port L2 Web Smart Ethernet PoE Switch 17 QoS Setting TCP UDP Port Based 6 7 Security Security MAC Address Binding ...

Страница 19: ...VT 16P250WS VT 24P370WS 16 24 Port L2 Web Smart Ethernet PoE Switch 18 Security TCP UDP Filter 6 8 Spanning Tree Spanning Tree STP Bridge Settings ...

Страница 20: ...VT 16P250WS VT 24P370WS 16 24 Port L2 Web Smart Ethernet PoE Switch 19 Spanning Tree STP Port Settings Spanning Tree Loopback Detection ...

Страница 21: ... Trunking Trunking Link Aggregation Settings The Trunking function allows the switch to combine two or four ports together to increase bandwidth Select the Trunking Groups choose the Members to be grouped together and then click Submit to activate the selected Trunking Groups ...

Страница 22: ... Switch 21 6 10 DHCP Relay Agent DHCP Relay Agent DHCP Relay Agent DHCP Relay Agent Relay Server DHCP Relay Agent VLAN MAP Relay Agent 6 11 Backup Recovery Allow the current configuration settings to be saved to a file not including the password and if necessary ...

Страница 23: ...to or from your local drive Click Download to save the current settings to your disk Click Browse to browse your computer for a saved backup settings file Click Update after selecting the backup settings file you want to restore Note Switch will reboot after restore and all current configurations will be lost 6 12 Miscellaneous Miscellaneous Miscellaneous Settings ...

Страница 24: ...b Smart Ethernet PoE Switch 23 6 13 SNMP Settings 6 14 Logout Click this to end this session Note If you close the web browser without clicking the Logout button it will be seen as an abnormal exit and the login session will still be occupied ...

Страница 25: ...The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes A PD shall return Class 0 to 4 in accordance with the maximum power draw as specified by following Table Class Usage Range of maximum power used by the PD 0 Default 0 44 to 12 95 Watts 1 Optional 0 44 to 3 84 Watts 2 Optional 3 84 to 6 49 Watts 3 Optional 6 49 to 12 95 Watts 4 Op...

Страница 26: ...for PoE port as default value does not provide power Note Please enable NTP and correct the System Time first As default value all PoE Schedule Profile functions are disabled Please use mouse to click on the block about what time you want to supply power for PoE port PoE NTP Setting This section provide the NTP Configuration of PoE Switch ...

Страница 27: ... to current location PoE PoE Auto check The PoE Switch can be configured to monitor connected PD s status in real time via ping action Once the PD stops working and without response the PoE Switch is going to restart PoE port power and bring the PD back to work It will greatly enhance the reliability and reduces administrator management burden If you do not fill in autoping address will have the f...

Страница 28: ...the port witch you want to set IPAddress IPAddress Allow assign IP address witch you want to monitor Checking Time Select time interval of ping action 1 10Min Reset Delay Time Select time PD Reset time 1 3Seconds Enable Checking Port No Select the port witch you want to enable PoE Auto check ...

Страница 29: ...ort Upgrade Firmware via WEB Built in Noiseless FAN 100V 240V AC 50 60Hz 400W 370W for PoE 32º 104ºF 0º 40ºC 20 85 RH 20 85 non condensing Detailed Specifications VT 16P250WS Ports PoE ports PoE Standard Pin assignment PoE ON OFF Control PoE Current Used PoE Powered Used PoE Schedule PoE PD Alive Auto Check PoE NTP LED Indicators Layer 2 Switching capacity MAC address table Jumbo Frame Port Featur...

Страница 30: ...vance replacement for a defective product however all related costs including but not limited to shipping and or delivery charges will be the responsibility of the customer If upon return inspection a product is determined to be in good working order or shows evidence of misuse the customer will be responsible for full payment of the original product purchased as well as the replacement product Be...

Отзывы: